Your browser doesn't support javascript.
loading
Multi-contrast diffraction enhanced computed laminography at Beijing Synchrotron Radiation Facility.
Fu, Jian; Shi, Xianhong; Yuan, Qingxi; Huang, Wanxia; Guo, Wei; Peng, Peng.
Afiliação
  • Fu J; Research Center of Digital Radiation Imaging and Biomedical Imaging, Beijing University of Aeronautics and Astronautics, Beijing, 100191, China. fujian706@buaa.edu.cn.
  • Shi X; Research Center of Digital Radiation Imaging and Biomedical Imaging, Beijing University of Aeronautics and Astronautics, Beijing, 100191, China.
  • Yuan Q; Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China.
  • Huang W; Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China.
  • Guo W; Research Center of Digital Radiation Imaging and Biomedical Imaging, Beijing University of Aeronautics and Astronautics, Beijing, 100191, China.
  • Peng P; Research Center of Digital Radiation Imaging and Biomedical Imaging, Beijing University of Aeronautics and Astronautics, Beijing, 100191, China.
Anal Bioanal Chem ; 410(27): 7221-7228, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30171283
ABSTRACT
Synchrotron radiation X-ray computed tomography (CT) enables nondestructive visualization of 3D morphological and chemical changes inside a sample and has become a powerful analysis tool to monitor reactive parts and their chemical states. However, synchrotron radiation CT imaging of specimens with lateral extensions much larger than the acceptance window of detectors is rather problematic due to strong absorption of X-rays in the lateral directions. On the other hand, X-ray computed laminography (CL) permits 3D imaging of flat samples while X-ray diffraction enhanced imaging (DEI) can provide high-quality results with different imaging contrasts such as absorption, phase and dark-field for samples with weak absorptions. Combining CL and DEI together, we have developed a multi-contrast DEI-CL system at the 4W1A beamline of the Beijing Synchrotron Radiation Facility for this kind of sample. Here we reported its design, implementation, and preliminary experimental results of carbon fiber reinforced polymer laminates with three kinds of imaging contrasts. The results have demonstrated the validity of this DEI-CL system. It will be helpful to push the applications of the state-of-the-art synchrotron radiation methods and instruments towards cutting-edge research. Graphical abstract ᅟ.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article