Your browser doesn't support javascript.
loading
Evaluation of Corneal Biomechanical Changes After Collagen Crosslinking in Patients with Progressive Keratoconus by Ocular Response Analyzer.
Küçümen, Raciha Beril; Sahan, Berna; Yildirim, Canan Asli; Çiftçi, Ferda.
Afiliação
  • Küçümen RB; Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey.
  • Sahan B; Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey.
  • Yildirim CA; Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, Izmir, Turkey.
  • Çiftçi F; Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey.
Turk J Ophthalmol ; 48(4): 160-165, 2018 Aug.
Article em En | MEDLINE | ID: mdl-30202610
ABSTRACT

OBJECTIVES:

To evaluate corneal biomechanics before and after collagen crosslinking (CXL) in patients with progressive keratoconus. MATERIALS AND

METHODS:

In this prospective study, CXL was performed under topical anesthesia after removal of the epithelium (epi-off technique) by applying ultraviolet A (UVA) light at a wavelength of 365 nm and power of 3 mW/cm2 or 5.4 joule/cm2. Isoosmolar 0.1% riboflavin solution was administered before and during UVA irradiation. In addition to ophthalmologic examination, ocular response analyzer measurements were performed pre- and postoperatively. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated intraocular pressure (IOPcc), Goldmann-correlated intraocular pressure (IOPg), and central corneal thickness (CCT) were recorded.

RESULTS:

The study included 35 eyes of 30 patients with progressive keratoconus. The mean age was 28.2±6.5 years and postoperative follow-up time was 20.2±14.7 months (range 6-74 months). The mean CH was 8.60±1.23 mmHg preoperatively, 8.96±2.05 mmHg in the early postoperative period (1-6 months), (p=0.28) and 8.96±1.28 mmHg in the late postoperative period (10-29 months) (p=0.48). Mean CRF was 7.13±1.50 mmHg preoperatively, 8.48±2.16 mmHg in the early postoperative period (p=0.009), and 7.71±1.29 mmHg in the late postoperative period (p=0.40). Mean IOPcc was 12.78±2.34 mmHg preoperatively, 15.38±4.21 mmHg in the early postoperative period (p=0.12) and 13.68±3.61 mmHg in the late postoperative period (p=0.48). Mean IOPg was 9.56±2.73 mmHg preoperatively, 13.01±4.45 mmHg in the early postoperative period (p=0.046), and 10.86±3.47 mmHg in the late postoperative period (p=0.44). Mean CCT was 484.43±41.26 µm preoperatively, 474.16±64.74 µm in the early postoperative period (p=0.70), and 470.38±33.64 µm in late postoperative period (p=0.71).

CONCLUSION:

CXL is a treatment modality believed to affect corneal biomechanics in keratoconus, but the results of larger patient series with longer follow-up periods may enable a better evaluation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article