Your browser doesn't support javascript.
loading
LISA improves statistical analysis for fMRI.
Lohmann, Gabriele; Stelzer, Johannes; Lacosse, Eric; Kumar, Vinod J; Mueller, Karsten; Kuehn, Esther; Grodd, Wolfgang; Scheffler, Klaus.
Afiliação
  • Lohmann G; Department of Biomedical Magnetic Resonance Imaging, University Hospital Tübingen, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany. gabriele.lohmann@tuebingen.mpg.de.
  • Stelzer J; Magnetic Resonance Centre, Max-Planck-Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076, Tübingen, Germany. gabriele.lohmann@tuebingen.mpg.de.
  • Lacosse E; Department of Biomedical Magnetic Resonance Imaging, University Hospital Tübingen, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany.
  • Kumar VJ; Magnetic Resonance Centre, Max-Planck-Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076, Tübingen, Germany.
  • Mueller K; Magnetic Resonance Centre, Max-Planck-Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076, Tübingen, Germany.
  • Kuehn E; Max-Planck-Institute for Intelligent Systems, Max-Planck-Ring 4, 72076, Tübingen, Germany.
  • Grodd W; Magnetic Resonance Centre, Max-Planck-Institute for Biological Cybernetics, Max-Planck-Ring 11, 72076, Tübingen, Germany.
  • Scheffler K; Methods & Development Group Nuclear Magnetic Resonance, Max-Planck-Institute for Human Cognitive and Brain Sciences, Stephanstrasse 1A, 04103, Leipzig, Germany.
Nat Commun ; 9(1): 4014, 2018 10 01.
Article em En | MEDLINE | ID: mdl-30275541
ABSTRACT
One of the principal goals in functional magnetic resonance imaging (fMRI) is the detection of local activation in the human brain. However, lack of statistical power and inflated false positive rates have recently been identified as major problems in this regard. Here, we propose a non-parametric and threshold-free framework called LISA to address this demand. It uses a non-linear filter for incorporating spatial context without sacrificing spatial precision. Multiple comparison correction is achieved by controlling the false discovery rate in the filtered maps. Compared to widely used other methods, it shows a boost in statistical power and allows to find small activation areas that have previously evaded detection. The spatial sensitivity of LISA makes it especially suitable for the analysis of high-resolution fMRI data acquired at ultrahigh field (≥7 Tesla).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Encéfalo / Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Encéfalo / Mapeamento Encefálico / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article