Your browser doesn't support javascript.
loading
Reliability and validity of the French version of the global physical activity questionnaire.
Rivière, Fabien; Widad, Fatima Zahra; Speyer, Elodie; Erpelding, Marie-Line; Escalon, Hélène; Vuillemin, Anne.
Afiliação
  • Rivière F; EA 4360 APEMAC, University of Lorraine, Paris Descartes University, Nancy 54505, France.
  • Widad FZ; EA 4360 APEMAC, University of Lorraine, Paris Descartes University, Nancy 54505, France.
  • Speyer E; EA 4360 APEMAC, University of Lorraine, Paris Descartes University, Nancy 54505, France.
  • Erpelding ML; Inserm, CIC-1433 Clinical Epidemiology, Nancy F-54000, France.
  • Escalon H; University Hospital Center of Nancy, Pole S2R, Epidemiology and Clinical Evaluation, Nancy F-54000, France.
  • Vuillemin A; Inserm, CIC-1433 Clinical Epidemiology, Nancy F-54000, France.
J Sport Health Sci ; 7(3): 339-345, 2018 Jul.
Article em En | MEDLINE | ID: mdl-30356654
ABSTRACT

BACKGROUND:

The Global Physical Activity Questionnaire (GPAQ) has been used to measure physical activity (PA) and sedentary time in France, but no study has assessed its psychometric properties. This study aimed to compare the reliability as well as criterion and concurrent validity of the French version of the GPAQ with the French International Physical Activity Questionnaire long form (IPAQ-LF) and use of an accelerometer in a general adult population.

METHODS:

We included 92 participants (students or staff) from the Medicine Campus at the University of Lorraine, Nancy (north-eastern France). The French GPAQ was completed twice, 7 days apart, to study test-retest reliability. The IPAQ-LF was used to assess concurrent validity of the GPAQ, and participants wore an accelerometer (ActiGraph GT3X+) for 7 days to study criterion validity. Reliability as well as concurrent and criterion validity of the GPAQ were tested by the intraclass correlation coefficient (ICC), Spearman correlation coefficient for quantitative variables, and Kappa and Phi coefficients for qualitative variables. Both concurrent and criterion validity of GPAQ were assessed by Bland-Altman plots.

RESULTS:

The GPAQ showed poor to good reliability (ICC = 0.37-0.94; Kappa = 0.50-0.62) and concurrent validity (Spearman r = 0.41-0.86), but only poor criterion validity (Spearman r = -0.22-0.42). Limits of agreement for the GPAQ and accelerometer were wide, with differences between 286.5 min/week and 601.3 min/week.

CONCLUSION:

The French version of the GPAQ provides limited but acceptable reliability and validity for the measurement of PA and sedentary time. It may be used for assessing PA and sedentary time in a French adult population.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Qualitative_research Idioma: En Ano de publicação: 2018 Tipo de documento: Article