Your browser doesn't support javascript.
loading
In-mask temperature and humidity can validate respirator wear-time and indicate lung health status.
Cherrie, John W; Wang, Shuohui; Mueller, William; Wendelboe-Nelson, Charlotte; Loh, Miranda.
Afiliação
  • Cherrie JW; Heriot Watt University, Institute of Biological Chemistry, Biophysics and Bioengineering, Edinburgh, EH14 4AS, UK. j.cherrie@hw.ac.uk.
  • Wang S; Centre for Human Exposure Science, Institute of Occupational Medicine, Research Avenue North, Edinburgh, EH14 4AP, UK. j.cherrie@hw.ac.uk.
  • Mueller W; Heriot Watt University, Institute of Biological Chemistry, Biophysics and Bioengineering, Edinburgh, EH14 4AS, UK.
  • Wendelboe-Nelson C; Centre for Human Exposure Science, Institute of Occupational Medicine, Research Avenue North, Edinburgh, EH14 4AP, UK.
  • Loh M; Heriot Watt University, Institute of Biological Chemistry, Biophysics and Bioengineering, Edinburgh, EH14 4AS, UK.
J Expo Sci Environ Epidemiol ; 29(4): 578-583, 2019 06.
Article em En | MEDLINE | ID: mdl-30382241
ABSTRACT
The effectiveness of respiratory protection is dependent on many factors, including the duration and times during the day when it is worn. To date, these factors could only be assessed by direct observation of the respirator user. We describe the novel use of a data-logging temperature and humidity sensor (iButton Hygrochron) located inside a facemask to quantify respirator wear-time through supervised experiments (Phase 1) and an unsupervised wearing trial (Phase 2). Additionally, in Phase 1 the in-mask temperature was compared with measurements of exhaled breath temperature. We found humidity responds more rapidly than temperature to donning a mask, so it was considered a more sensitive measure of wear-time, particularly for short durations. Supervised tests showed that this method can provide accurate and precise estimates of wear-time, although the approach may be unsuitable for use in situations where there is high ambient humidity. In-mask temperature is closely associated with exhaled breath temperature, which is linked to lung inflammation. This technique could provide a useful way of evaluating the effectiveness of respirators in protecting health in real-life situations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Temperatura / Umidade / Pulmão Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Temperatura / Umidade / Pulmão Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article