Your browser doesn't support javascript.
loading
Multi-element analysis of size-segregated fine and ultrafine particulate via Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry.
Rovelli, Sabrina; Nischkauer, Winfried; Cavallo, Domenico M; Limbeck, Andreas.
Afiliação
  • Rovelli S; Department of Science and High Technology, University of Insubria, via Valleggio 11, 22100, Como, Italy. Electronic address: sabrina.rovelli@uninsubria.it.
  • Nischkauer W; Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria. Electronic address: winfried.nischkauer@tuwien.ac.at.
  • Cavallo DM; Department of Science and High Technology, University of Insubria, via Valleggio 11, 22100, Como, Italy. Electronic address: domenico.cavallo@uninsubria.it.
  • Limbeck A; Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9/164-IAC, A-1060, Vienna, Austria. Electronic address: A.Limbeck@tuwien.ac.at.
Anal Chim Acta ; 1043: 11-19, 2018 Dec 28.
Article em En | MEDLINE | ID: mdl-30392658
ABSTRACT
In this study a novel and reliable Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) measurement protocol for the elemental characterization of size-segregated particulate was developed. Special efforts were made to improve and optimize sample pre-treatment steps and LA operating conditions to avoid some critical drawbacks encountered during analysis and to make the particulate samples suitable for an accurate and reproducible LA-ICP-MS analysis, regardless of the mass loading on each filter. For example, a new approach for dust-fixation on the sample-carrier was developed using a glycerol coverage, which allowed to overcome problematic sample losses during the ablation process. Under the optimum conditions, dust samples, blank filters and standards for calibration were analyzed by multiple rastering of defined spot areas. Quantitative analysis was accomplished with dried micro-droplets of aqueous standard solutions. Derived method detection limits varied between 0.001 and 0.1 ng m-3 and allowed even for the smallest particle fraction quantitative measurements. The accuracy of LA-ICP-MS results was verified by comparison with conventional ICP-MS analysis of selected PM samples after sample mineralization. The proposed LA treatment procedure benefits from a simple and fast sample preparation, thus overcoming the laborious pre-treatment steps required for wet chemical digestion. Moreover, the better sensitivity of the LA-ICP-MS approach provided more complete information about the mass concentration and size-distribution of the investigated elements, thus allowing to deeper investigate the composition of the most dangerous PM fractions in terms of health concern.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2018 Tipo de documento: Article