Your browser doesn't support javascript.
loading
Quantification of DEET and neonicotinoid pesticide biomarkers in human urine by online solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry.
Baker, Samuel E; Serafim, Amanda Bishop; Morales-Agudelo, Pilar; Vidal, Meghan; Calafat, Antonia M; Ospina, Maria.
Afiliação
  • Baker SE; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, MS F17, Atlanta, GA, 30341, USA.
  • Serafim AB; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, MS F17, Atlanta, GA, 30341, USA.
  • Morales-Agudelo P; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, MS F17, Atlanta, GA, 30341, USA.
  • Vidal M; Battelle Memorial Institute, 2987 Clairmont Rd, Suite 450, Atlanta, GA, 30329, USA.
  • Calafat AM; Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy, MS F17, Atlanta, GA, 30341, USA.
  • Ospina M; Battelle Memorial Institute, 2987 Clairmont Rd, Suite 450, Atlanta, GA, 30329, USA.
Anal Bioanal Chem ; 411(3): 669-678, 2019 Jan.
Article em En | MEDLINE | ID: mdl-30483854
ABSTRACT
Neonicotinoid insecticides are widely used replacements for organophosphate and carbamate insecticides, but the extent of human exposure is largely unknown. On the other hand, based on urinary concentrations of DEET metabolites, human exposure to N,N-diethyl-m-toluamide (DEET) appears to be widespread. We developed a fast online solid-phase extraction high-performance liquid chromatography-isotope dilution tandem mass spectrometry (HPLC-MS/MS) method to measure in 200 µL of human urine the concentrations of six neonicotinoid biomarkers (acetamiprid, N-desmethyl-acetamiprid, clothianidin, imidacloprid, 5-hydroxy-imidacloprid, thiacloprid), and two DEET biomarkers (3-diethyl-carbamoyl benzoic acid, 3-ethyl-carbamoyl benzoic acid). Limits of detection ranged from 0.01 to 0.1 µg/L, depending on the biomarker. Accuracy ranged from 91 to 116% and precision ranged from 3.7 to 10 %RSD. The presented method can be used to increase our understanding of exposure to neonicotinoid insecticides and DEET, and to evaluate the potential health effects from such exposures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / DEET / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Neonicotinoides / Repelentes de Insetos / Inseticidas Limite: Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / DEET / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Neonicotinoides / Repelentes de Insetos / Inseticidas Limite: Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article