Your browser doesn't support javascript.
loading
Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance.
Peper, Eva S; Strijkers, Gustav J; Gazzola, Katja; Potters, Wouter V; Motaal, Abdallah G; Luirink, Ilse K; Hutten, Barbara A; Wiegman, Albert; van Ooij, Pim; van den Born, Bert-Jan H; Nederveen, Aart J; Coolen, Bram F.
Afiliação
  • Peper ES; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Strijkers GJ; Department of Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Gazzola K; Department of Vascular Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Potters WV; Department of Neurology, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Motaal AG; Image Guided Therapy, Philips Healthcare, Singapore, Singapore.
  • Luirink IK; Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Hutten BA; Department of Pediatrics Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Wiegman A; Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • van Ooij P; Department of Pediatrics Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • van den Born BH; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Nederveen AJ; Department of Vascular Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
  • Coolen BF; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands.
J Cardiovasc Magn Reson ; 20(1): 86, 2018 12 20.
Article em En | MEDLINE | ID: mdl-30567566
ABSTRACT

BACKGROUND:

Cardiovascular magnetic resonance (CMR) allows for non-invasive assessment of arterial stiffness by means of measuring pulse wave velocity (PWV). PWV can be calculated from the time shift between two time-resolved flow curves acquired at two locations within an arterial segment. These flow curves can be derived from two-dimensional CINE phase contrast CMR (2D CINE PC CMR). While CMR-derived PWV measurements have proven to be accurate for the aorta, this is more challenging for smaller arteries such as the carotids due to the need for both high spatial and temporal resolution. In this work, we present a novel method that combines retrospectively gated 2D CINE PC CMR, high temporal binning of data and compressed sensing (CS) reconstruction to accomplish a temporal resolution of 4 ms. This enables accurate flow measurements and assessment of PWV in regional carotid artery segments.

METHODS:

Retrospectively gated 2D CINE PC CMR data acquired in the carotid artery was binned into cardiac frames of 4 ms length, resulting in an incoherently undersampled ky-t-space with a mean undersampling factor of 5. The images were reconstructed by a non-linear CS reconstruction using total variation over time as a sparsifying transform. PWV values were calculated from flow curves by using foot-to-foot and cross-correlation methods. Our method was validated against ultrasound measurements in a flow phantom setup representing the carotid artery. Additionally, PWV values of two groups of 23 young (30 ± 3 years, 12 [52%] women) and 10 elderly (62 ± 10 years, 5 [50%] women) healthy subjects were compared using the Wilcoxon rank-sum test.

RESULTS:

Our proposed method produced very similar flow curves as those measured using ultrasound at 1 ms temporal resolution. Reliable PWV estimation proved possible for transit times down to 7.5 ms. Furthermore, significant differences in PWV values between healthy young and elderly subjects were found (4.7 ± 1.0 m/s and 7.9 ± 2.4 m/s, respectively; p < 0.001) in accordance with literature.

CONCLUSIONS:

Retrospectively gated 2D CINE PC CMR with CS allows for high spatiotemporal resolution flow measurements and accurate regional carotid artery PWV calculations. We foresee this technique will be valuable in protocols investigating early development of carotid atherosclerosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Artérias Carótidas / Doenças das Artérias Carótidas / Imagem Cinética por Ressonância Magnética / Compressão de Dados / Rigidez Vascular Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Artérias Carótidas / Doenças das Artérias Carótidas / Imagem Cinética por Ressonância Magnética / Compressão de Dados / Rigidez Vascular Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article