Your browser doesn't support javascript.
loading
Determination of 89Sr and 90Sr in fresh cow milk and raw urine using crystalline synthetic tunnel manganese oxides and layered metal sulfides.
Pittet, Pierre-André; Bochud, François; Froidevaux, Pascal.
Afiliação
  • Pittet PA; Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland.
  • Bochud F; Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland.
  • Froidevaux P; Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland. Electronic address: pascal.froidevaux@chuv.ch.
Anal Chim Acta ; 1047: 267-274, 2019 Jan 24.
Article em En | MEDLINE | ID: mdl-30567659
89Sr and 90Sr are both fission products of high radiotoxicity, which can be released in significant amounts in the event of a nuclear accident. Radiostrontium isotopes will follow calcium all along the food chain and, after ingestion, accumulate in the bones. Therefore, it is imperative to be able to determine 89Sr and 90Sr in raw milk samples in case of an accidental situation to evaluate the dose given by both radionuclides to the population. Several methods exist for conducting 89Sr and 90Sr determination. However, most of them use at least one chromatographic step to purify strontium. This, unfortunately, increases the analytical time before the results can be released to the authorities. In addition, they often use liquid scintillation counting to determine the 89Sr and 90Sr activities, a method which can handle only one sample at a time. Here we propose using synthetic tunnel manganese oxides such as cryptomelane and todorokite and layered metal sulfides to selectively extract strontium from fresh milk and raw urine in a batch sorption method. We found that the method is very quick and yields very pure sources of (radio)-strontium, which can be counted in a proportional counter. Data (counts per minute) from the counter were fitted to a mathematical expression enabling the simultaneous determination of 89Sr and 90Sr. Because a proportional counter often has several drawers, it is typically possible to measure up to 16 samples at a time. Since cryptomelane is a binding phase easily synthesized in a large quantity, we anticipate that this technique could be an interesting alternative to conventional solid phase extraction chromatography methods.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Radioisótopos de Estrôncio / Sulfetos / Contaminação de Alimentos / Compostos de Manganês / Leite Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Radioisótopos de Estrôncio / Sulfetos / Contaminação de Alimentos / Compostos de Manganês / Leite Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article