  • Elter A; Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), INF 280, 69120 Heidelberg, Germany. Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany. National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
Phys Med Biol ; 64(4): 04NT02, 2019 02 08.
Article em En | MEDLINE | ID: mdl-30650389
ABSTRACT
Polymer gel (PG) dosimetry enables three dimensional (3D) measurement of complex dose distributions. However, PGs are strongly reactive with oxygen and other contaminations, limiting their applicability by the need to use specific container materials. We investigate different 3D printing materials and printing techniques for their compatibility with PG. Suitable 3D printing materials may provide the possibility to perform PG dosimetry in complex-shaped phantoms. 3D printed and PG-filled test vials were irradiated homogenously. The signal response was evaluated with respect to homogeneity and compared to the signal in already validated reference vials. In addition, for the printing material VeroClear™ (StrataSys, Eden Prairie, USA) different methods to remove support material, which was required during the printing process, were investigated. We found that the support material should be used only on the outer side of the container wall with no direct contact to the PG. With the VeroClear™ material a homogenous signal response was achieved with a mean deviation of [Formula see text] relative to the reference vials. In addition, the homogeneous irradiation of an irregularly-shaped gel container designed with the same printing material and technique also lead to a homogenous PG response. Furthermore, a small field irradiation of an additional test-vial showed an accurate representation of steep dose gradients with a deviation of the maximum position of [Formula see text] relative to the reference vial.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Polímeros / Radiometria / Imagens de Fantasmas / Impressão Tridimensional / Géis Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Polímeros / Radiometria / Imagens de Fantasmas / Impressão Tridimensional / Géis Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article