Your browser doesn't support javascript.
loading
Circular Estimate Method (CEM) - a Simple Method to Estimate Caenorhabditis elegans Culture Densities in Liquid Medium.
Josende, Marcelo Estrella; Nunes, Silvana Manske; Müller, Larissa; Ferreira-Cravo, Marlize; Monserrat, José Marìa; Ventura-Lima, Juliane.
Afiliação
  • Josende ME; 1Instituto de Ciências Biológicas (ICB), Universidade Federal do Rio Grande - FURG, Av. Itália km 8, Rio Grande, RS 96203-900 Brazil.
  • Nunes SM; Programa de Pós-Graduação em Ciências Fisiológicas (PPGCF) - FURG, Rio Grande, Brazil.
  • Müller L; 1Instituto de Ciências Biológicas (ICB), Universidade Federal do Rio Grande - FURG, Av. Itália km 8, Rio Grande, RS 96203-900 Brazil.
  • Ferreira-Cravo M; Programa de Pós-Graduação em Ciências Fisiológicas (PPGCF) - FURG, Rio Grande, Brazil.
  • Monserrat JM; 1Instituto de Ciências Biológicas (ICB), Universidade Federal do Rio Grande - FURG, Av. Itália km 8, Rio Grande, RS 96203-900 Brazil.
  • Ventura-Lima J; Programa de Pós-Graduação em Ciências Fisiológicas (PPGCF) - FURG, Rio Grande, Brazil.
Biol Proced Online ; 21: 1, 2019.
Article em En | MEDLINE | ID: mdl-30675134
ABSTRACT

BACKGROUND:

Nematodes are used in many different fields of science, including environmental and biomedical research. Counting and/or estimating nematode numbers is required during research. Although being one of the most common procedures, this apparently simple task is a time-consuming process, prone to errors and concerns regarding procedure, reliability, and accuracy. When an estimate is necessary, there is a traditional manual counting procedure that in this study it will be called as "drop method" (DM). This popular method that extrapolates an animal count from a small drop of fluid shows a high coefficient of variation. To solve this problem, the present study used the free-living nematode Caenorhabditis elegans to develop a new estimation procedure that was based on a relationship between area and volume of a larger sample.

RESULTS:

The new method showed a low coefficient of variation and a close relationship between estimated and real counts of the total number of nematodes in large C. elegans suspensions. Reactive oxygen concentration was measured as an example of method application and to allow comparison between methods.

CONCLUSION:

The proposed method is accurate, facile and reproducible, requiring simple, inexpensive materials that make it an excellent alternative to the DM manual counting procedure. Although the DM is faster, its estimates are not as accurate or as precise as those of the new proposed method.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article