Your browser doesn't support javascript.
loading
Correlative Atom Probe Tomography and Transmission Electron Microscopy Analysis of Grain Boundaries in Thermally Grown Alumina Scale.
Povstugar, Ivan; Weber, Juliane; Naumenko, Dmitry; Huang, Taihong; Klinkenberg, Martina; Quadakkers, Willem J.
Afiliação
  • Povstugar I; Central Institute for Engineering, Electronics and Analytics (ZEA-3) -- Analytics,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
  • Weber J; Institute of Energy and Climate Research (IEK-6) -- Nuclear Waste Management and Reactor Safety,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
  • Naumenko D; Institute of Energy and Climate Research (IEK-2) -- Microstructure and Properties of Materials,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
  • Huang T; Institute of Energy and Climate Research (IEK-2) -- Microstructure and Properties of Materials,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
  • Klinkenberg M; Institute of Energy and Climate Research (IEK-6) -- Nuclear Waste Management and Reactor Safety,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
  • Quadakkers WJ; Institute of Energy and Climate Research (IEK-2) -- Microstructure and Properties of Materials,Forschungszentrum Jülich GmbH, 52425 Jülich,Germany.
Microsc Microanal ; 25(1): 11-20, 2019 02.
Article em En | MEDLINE | ID: mdl-30712525
We employed correlative atom probe tomography (APT) and transmission electron microscopy (TEM) to analyze the alumina scale thermally grown on the oxide dispersion-strengthened alloy MA956. Segregation of Ti and Y and associated variation in metal/oxygen stoichiometry at the grain boundaries and triple junctions of alumina were quantified and discussed with respect to the oxidation behavior of the alloy, in particular, to the formation of cation vacancies. Correlative TEM analysis was helpful to avoid building pragmatically well-looking but substantially incorrect APT reconstructions, which can result in erroneous quantification of segregating species, and highlights the need to consider ionic volumes and detection efficiency in the reconstruction routine. We also demonstrate a cost-efficient, robust, and easy-handling setup for correlative analysis based solely on commercially available components, which can be used with all conventional TEM tools without the need to modify the specimen holder assembly.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article