Your browser doesn't support javascript.
loading
An Automated Computational Approach for Complete In-Plane Compositional Interface Analysis by Atom Probe Tomography.
Peng, Zirong; Lu, Yifeng; Hatzoglou, Constantinos; Kwiatkowski da Silva, Alisson; Vurpillot, Francois; Ponge, Dirk; Raabe, Dierk; Gault, Baptiste.
Afiliação
  • Peng Z; Department of Microstructure Physics and Alloy Design,Max-Planck-Institut für Eisenforschung GmbH,Max-Planck-Straße 1, 40237 Düsseldorf,Germany.
  • Lu Y; Database Systems and Data Mining Group,Ludwig-Maximilians-Universität München,Oettingenstraße 67, 80538 München,Germany.
  • Hatzoglou C; Normandie Univ, UNIROUEN, INSA Rouen, CNRS, GPM,76000 Rouen,France.
  • Kwiatkowski da Silva A; Department of Microstructure Physics and Alloy Design,Max-Planck-Institut für Eisenforschung GmbH,Max-Planck-Straße 1, 40237 Düsseldorf,Germany.
  • Vurpillot F; Normandie Univ, UNIROUEN, INSA Rouen, CNRS, GPM,76000 Rouen,France.
  • Ponge D; Department of Microstructure Physics and Alloy Design,Max-Planck-Institut für Eisenforschung GmbH,Max-Planck-Straße 1, 40237 Düsseldorf,Germany.
  • Raabe D; Department of Microstructure Physics and Alloy Design,Max-Planck-Institut für Eisenforschung GmbH,Max-Planck-Straße 1, 40237 Düsseldorf,Germany.
  • Gault B; Department of Microstructure Physics and Alloy Design,Max-Planck-Institut für Eisenforschung GmbH,Max-Planck-Straße 1, 40237 Düsseldorf,Germany.
Microsc Microanal ; 25(2): 389-400, 2019 04.
Article em En | MEDLINE | ID: mdl-30722805
ABSTRACT
We introduce an efficient, automated computational approach for analyzing interfaces within atom probe tomography datasets, enabling quantitative mapping of their thickness, composition, as well as the Gibbsian interfacial excess of each solute. Detailed evaluation of an experimental dataset indicates that compared with the composition map, the interfacial excess map is more robust and exhibits a relatively higher resolution to reveal compositional variations. By field evaporation simulations with a predefined emitter mimicking the experimental dataset, the impact of trajectory aberrations on the measurement of the thickness, composition, and interfacial excess of the decorated interface are systematically analyzed and discussed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article