Fracture of the polyethylene tibial post in the posterior-stabilized total knee prosthesis: arthrographic and CT arthrographic diagnosis.
Hsu, Yung; Lin, Chien-Hung; Shu, Ginger H F; Hsieh, Tsyh-Jyi; Chen, Clement Kuen-Huang.
Afiliação
  • Hsu Y; Department of Medical Imaging, Chi Mei Medical Center, Yongkang, No. 901, Zhonghua Rd Yongkang District, Tainan City, 71004, Taiwan.
  • Lin CH; Department of Medical Imaging, Chi Mei Medical Center, Yongkang, No. 901, Zhonghua Rd Yongkang District, Tainan City, 71004, Taiwan.
  • Shu GHF; Department of Medical Imaging, Chi Mei Medical Center, Chiali, No. 606, Jialixing Xinghua Village, Jiali District, Tainan City, 72263, Taiwan.
  • Hsieh TJ; Department of Medical Imaging, Chi Mei Medical Center, Yongkang, No. 901, Zhonghua Rd Yongkang District, Tainan City, 71004, Taiwan.
  • Chen CK; Department of Medical Imaging, Chi Mei Medical Center, Yongkang, No. 901, Zhonghua Rd Yongkang District, Tainan City, 71004, Taiwan. ckhc821@gmail.com.
Skeletal Radiol ; 48(7): 1145-1148, 2019 Jul.
Article em En | MEDLINE | ID: mdl-30729263
Fracture of the polyethylene tibial post in the posterior-stabilized total knee prosthesis is often delayed in diagnosis due to its nonspecific symptoms and the radiolucent characteristic of polyethylene on conventional radiography. Therefore, the diagnosis is always established by arthroscopy. Notwithstanding recent advances in imaging modalities, we are presently aware of only two related case reports on MRI and even no reports about arthrographic or CT-arthrographic diagnosis of fractured tibial post. We hereby report a case of a 58-year-old female patient who developed recurrent knee pain during the third year after total knee arthroplasty. The displaced polyethylene tibial post was clearly outlined by administered contrast material in the posterior knee. Under the diagnosis of fracture of the tibial post, the patient underwent isolated replacement of the broken polyethylene insert. Her knee pain significantly improved after the operation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Tomografia Computadorizada por Raios X / Artroplastia do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Tomografia Computadorizada por Raios X / Artroplastia do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article