Your browser doesn't support javascript.
loading
Radiation dose in nuclear medicine: the hybrid imaging.
Salvatori, Massimo; Rizzo, Alessio; Rovera, Guido; Indovina, Luca; Schillaci, Orazio.
Afiliação
  • Salvatori M; Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Istituto di Medicina Nucleare, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome, 00168, Italy. massimo.salvatori@unicatt.it.
  • Rizzo A; Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Istituto di Medicina Nucleare, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome, 00168, Italy.
  • Rovera G; Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Istituto di Medicina Nucleare, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome, 00168, Italy.
  • Indovina L; Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy.
  • Schillaci O; Dipartimento di Biomedicina e Prevenzione, Università di Roma Tor Vergata, Rome, Italy.
Radiol Med ; 124(8): 768-776, 2019 Aug.
Article em En | MEDLINE | ID: mdl-30771217
ABSTRACT
Hybrid imaging procedures such as single-photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/computed tomography (PET/CT) showed a rapid diffusion in recent years because of their high sensitivity, specificity, and accuracy, due to a more accurate localization and definition of scintigraphic findings. However, hybrid systems inevitably lead to an increase in patient radiation exposure because of the added CT component. Effective doses due to the radiopharmaceuticals can be estimated by multiplying the administered activities by the effective dose coefficients, while for the CT component the dose-length product can be multiplied by a conversion coefficient k. However, the effective dose value is subject to a high degree of uncertainty and must be interpreted as a broad, generic estimate of biologic risk. Although the effective dose can be used to estimate and compare the risk of radiation exposure across multiple imaging techniques, clinicians should be aware that it represents a generic evaluation of the risk derived from a given procedure to a generic model of the human body. It cannot be applied to a single individual and should not be used for epidemiologic studies or the estimation of population risks due to the inherent uncertainties and oversimplifications involved. Practical ways to reduce radiation dose to patients eligible for hybrid imaging involve adjustments to both the planning phase and throughout the execution of the study. These methods include individual justification of radiation exposure, radiopharmaceutical choice, adherence to diagnostic reference levels (DLR), patient hydration and bladder voiding, adoption of new technical devices (sensitive detectors or collimators) with new reconstruction algorithms, and implementation of appropriate CT protocols and exposure parameters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Exposição à Radiação / Compostos Radiofarmacêuticos / Imagem Multimodal / Medicina Nuclear Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Exposição à Radiação / Compostos Radiofarmacêuticos / Imagem Multimodal / Medicina Nuclear Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article