Your browser doesn't support javascript.
loading
Multi-Steps Fragmentation-Ion Trap Mass Spectrometry Coupled to Liquid Chromatography Diode Array System for Investigation of Olaparib Related Substances.
Khedr, Alaa; El-Hay, Soad S Abd; Kammoun, Ahmed K.
Afiliação
  • Khedr A; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, P.O. Box 80260, Jeddah 21589, Saudi Arabia. akhedr@kau.edu.sa.
  • El-Hay SSA; Department of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, 44519 Zagazig, Egypt. soadselem@gmail.com.
  • Kammoun AK; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, P.O. Box 80260, Jeddah 21589, Saudi Arabia. akammoun@hotmail.com.
Molecules ; 24(5)2019 Feb 27.
Article em En | MEDLINE | ID: mdl-30818845
ABSTRACT
A high-performance liquid chromatography-diode array-mass spectrometric (LC-DAD-MS) method was developed and validated to investigate the related substances of olaparib (OLA) in bulk form. OLA was exposed to acid⁻base hydrolysis, boiling, oxidation with hydrogen peroxide, and UV light followed by LC-DAD-MS analysis. OLA and OLA-related substances were simultaneously and quantitatively monitored by DAD at 278 nm and triple quadrupole mass spectrometry (QQQ-MS). The investigated compounds were auto-scanned by an ion trap MS which applied positive and negative modes separately. The fragmentation pathway was confirmed by applying multi-steps fragmentation to identify the resulted cleaved ions and their parent ion. OLA was found to be sensitive to the alkaline hydrolysis and less sensitive to UV light. Two major hydrolytic degradation products, including the protonated molar ions m/z 299 and m/z 367, were identified. Three potential impurities were also characterized. The LC-MS limit of detection (LOD) and limit of quantification (LOQ) were 0.01 and 0.05 ng/µL, respectively. The quantitative results obtained by LC-DAD was comparable with that of LC-QQQ-MS. The proposed method shows good intra-day and inter-day precision with relative standard deviation (RSD) <2%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ftalazinas / Piperazinas / Cromatografia Líquida / Espectrometria de Massas por Ionização por Electrospray / Antineoplásicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ftalazinas / Piperazinas / Cromatografia Líquida / Espectrometria de Massas por Ionização por Electrospray / Antineoplásicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article