Your browser doesn't support javascript.
loading
VASIM: an automated tool for the quantification of carotid atherosclerosis by computed tomography angiography.
Caetano Dos Santos, Florentino Luciano; Kolasa, Marcin; Terada, Mitsugu; Salenius, Juha; Eskola, Hannu; Paci, Michelangelo.
Afiliação
  • Caetano Dos Santos FL; BioMediTech, Faculty of Medicine and Health Technology, Tampere University, SM312, Korkeakoulunkatu 3, 33720, Tampere, Finland. florentino.l.c.santos@ieee.org.
  • Kolasa M; Department of Radiology, Medical Imaging Center, Tampere University Hospital, Tampere, Finland. florentino.l.c.santos@ieee.org.
  • Terada M; BioMediTech, Faculty of Medicine and Health Technology, Tampere University, P.O. Box 692, Tampere, 33014, Finland. florentino.l.c.santos@ieee.org.
  • Salenius J; Department of Radiology, Medical Imaging Center, Tampere University Hospital, Tampere, Finland.
  • Eskola H; Department of Applied Physics, Faculty of Science, Fukuoka University, Fukuoka, Japan.
  • Paci M; Division of Vascular Surgery, Department of Surgery, Tampere University Hospital and Medical School, Tampere, Finland.
Int J Cardiovasc Imaging ; 35(6): 1149-1159, 2019 Jun.
Article em En | MEDLINE | ID: mdl-30820803
ABSTRACT
The diagnostic imaging techniques currently used to evaluate the arterial atherosclerosis hinge on the manual marking and calculation of the stenosis degree. However, the manual assessment is highly dependent on the operator and characterized by low replicability. The study aimed to develop a fully-automated tool for the segmentation and analysis of atherosclerosis in the extracranial carotid arteries. The dataset consisted of 59 randomly-chosen individuals who had undergone head-and-neck computed tomography angiography (CTA), at the Tampere University Hospital, Tampere, Finland. The analysis algorithm was mainly based on the detection of carotid arteries, delineation of the vascular wall, and extraction of the atherosclerotic plaque. To improve the vascular detection rate, the model-based and volume-wide analytical approaches were deployed. A new fully-automated vascular imaging (VASIM) software tool was developed. For stenosis over 50%, the success rate was 83% for the detection and segmentation. Specificity and sensitivity of the algorithm were 25% and 83%, respectively. The overall accuracy was 71%. The VASIM tool is the first published approach for the fully-automated analysis of atherosclerosis in extracranial carotid arteries. The tool provides new outputs, which may help with the quantitative and qualitative, clinical evaluation of the atherosclerosis burden and evolution. The findings from this study provide a basis for the further development of automated atherosclerosis diagnosis and plaque analysis with CTA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Artérias Carótidas / Estenose das Carótidas / Placa Aterosclerótica / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Artérias Carótidas / Estenose das Carótidas / Placa Aterosclerótica / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2019 Tipo de documento: Article