Prediction of maximal oxygen consumption using the Young Men's Christian Association-step test in Korean adults.
Lee, On; Lee, Sukho; Kang, Minsoo; Mun, Junbae; Chung, Jinwook.
Afiliação
  • Lee O; Korea Institute of Sport Science, 109, 727 Hwarang-ro, Nowon-gu, Seoul, 01794, South Korea.
  • Lee S; Department of Counseling, Health, and Kinesiology, College of Education and Human Development, Texas A&M University-San Antonio, One University Way, STEM 142A, San Antonio, TX, 78224, USA.
  • Kang M; Health, Exercise Science, and Recreation Management, The University of Mississippi, P.O. Box 1848, 219 Turner Center, University, MS, 38677-1848, USA.
  • Mun J; Department of Physical Education, Korea Military Academy, Seoul, South Korea.
  • Chung J; Sports Culture Department, Dongguk University, 101-492, 30, Pildong-ro 1 gil, Jung-gu, Seoul, 04620, South Korea. cjw826@dongguk.edu.
Eur J Appl Physiol ; 119(5): 1245-1252, 2019 May.
Article em En | MEDLINE | ID: mdl-30850877
ABSTRACT

PURPOSE:

To develop accurate and practical prediction models of maximal oxygen consumption (VO2max) using the Young Men's Christian Association (YMCA)-step test in South Korean adults.

METHODS:

In total, 568 adults (20-66 years) were included in this study. To develop and cross-validate prediction models of VO2max, the total sample was divided into 80% training and 20% testing using a simple random sampling method. VO2max was measured using the maximal-graded exercise treadmill test. Sex, age, 1-min recovery heart rate, body weight, and height were measured as potential predictors. Each test was conducted within a 2- to 3-day interval, ensuring sufficient rest. Preliminary prediction models were developed from training datasets, which were cross-validated using regression analyses and/or repeated-measures analysis of variance. The accuracy of prediction models was evaluated using R2, standard error of estimate (SEE), and mean difference (MD) against a criterion-measured VO2max.

RESULTS:

The average age and VO2max were 43.5 ± 12.9 years and 39.1 ± 7.5 ml/kg/min, respectively. For model development, three practical models with acceptable accuracy were developed (R2 = 0.56-0.61; SEE = 4.74-5.01). For model cross-validation, significant relationships between the criterion-measured and predicted VO2max were observed in all three models (R2 = 0.56-0.61; SEE = 4.62-4.88). The difference between criterion-measured and predicted VO2max was not significant in the models (MD =- 0.03 to - 0.14).

CONCLUSIONS:

The prediction models included 3-5 variables as significant predictors of VO2max and had acceptable accuracy in a large sample of South Korean adults. The selected models provide a simple and practical method to estimate VO2max using the YMCA-step test for South Korean adults.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Teste de Esforço Tipo de estudo: Guideline / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Teste de Esforço Tipo de estudo: Guideline / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article