Your browser doesn't support javascript.
loading
Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures.
Sollmann, Nico; Mei, Kai; Hedderich, Dennis M; Maegerlein, Christian; Kopp, Felix K; Löffler, Maximilian T; Zimmer, Claus; Rummeny, Ernst J; Kirschke, Jan S; Baum, Thomas; Noël, Peter B.
Afiliação
  • Sollmann N; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany. Nico.Sollmann@tum.de.
  • Mei K; TUM-Neuroimaging Center, Klinikum rechts der Isar, Technische Universität München, Munich, Germany. Nico.Sollmann@tum.de.
  • Hedderich DM; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich, Germany.
  • Maegerlein C; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Kopp FK; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Löffler MT; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich, Germany.
  • Zimmer C; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Rummeny EJ; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Kirschke JS; Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich, Germany.
  • Baum T; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
  • Noël PB; Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.
Eur Radiol ; 29(7): 3606-3616, 2019 Jul.
Article em En | MEDLINE | ID: mdl-30903337

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vértebras Torácicas / Vértebras Cervicais / Fraturas da Coluna Vertebral / Artefatos / Tomografia Computadorizada Multidetectores Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vértebras Torácicas / Vértebras Cervicais / Fraturas da Coluna Vertebral / Artefatos / Tomografia Computadorizada Multidetectores Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article