Your browser doesn't support javascript.
loading
Interprosthetic Femoral Sleeves in Revision Arthroplasty: A 20-Year Experience.
Abdelaziz, Hussein; Saleri, Solmaz; Mau, Hans; Sandiford, Nemandra A; Lausmann, Christian; Zahar, Akos; Gehrke, Thorsten; Haasper, Carl; Citak, Mustafa.
Afiliação
  • Abdelaziz H; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Saleri S; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Mau H; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Sandiford NA; Complex Arthroplasty Unit, St George's Hospital, London, UK.
  • Lausmann C; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Zahar A; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Gehrke T; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
  • Haasper C; Department of Orthopaedic Surgery, AMEOS Klinikum Seepark Geestland, Geestland, Germany.
  • Citak M; Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany.
J Arthroplasty ; 34(7): 1423-1429, 2019 07.
Article em En | MEDLINE | ID: mdl-30904363
ABSTRACT

BACKGROUND:

Interprosthetic femoral fractures in patients with ipsilateral stemmed total hip arthroplasty (THA) and total knee arthroplasty (TKA) can be technically demanding to treat surgically. Nonunion and implant failure are among the main complications following fixation of interprosthetic femoral (IF) fractures. Total femoral arthroplasty (TFA) is associated with a high incidence of infection and instability. IF sleeves have been designed to avoid the disadvantages of these techniques and to provide a stable construct. The aim of this study was to present the results with this device from a single center.

METHODS:

We reviewed 26 patients who underwent revision arthroplasty procedures, using custom-made cemented IF sleeves between 1997 and December 2017 in our institution. Two-part sleeves were used in 18 patients and one-part sleeves in 8 patients. The most common indication was an IF fracture (18 patients). Patients were monitored for postoperative complications, implant failure, and re-revision. The minimum follow-up of the survivors with nonrevised sleeves was 12 months.

RESULTS:

Twenty-three patients were included for the final analysis. The mean survivorship of the IF sleeve was 4.6 years at latest follow-up (mean 48.5 months; range 12 to 156). The overall rate of complications was 47.8%. The rate of mechanical failure was 21.7%. Late infections occurred in 3 patients (13%). At the latest follow-up, the mean Harris Hip Score was 69.9 points (range 39 to 94), and the mean functional Knee Society Score was 42.5 points (range 0 to 90), with average knee flexion of 95° (range 90° to 100°).

CONCLUSION:

The IF sleeve is a valid technique for the management of selected patients with IF fractures, particularly when a stable fracture fixation is not possible. Hip instability is not a concern, and functional improvement is achievable. Careful planning is required preoperatively to avoid mechanical failure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Fraturas do Fêmur / Fêmur Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Fraturas do Fêmur / Fêmur Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article