Your browser doesn't support javascript.
loading
A novel fluorescence immunoassay based on AgNCs and ALP for ultrasensitive detection of sulfamethazine (SMZ) in environmental and biological samples.
Zhu, Nuanfei; Zhu, Yuqi; Wang, Jin; Gyimah, Eric; Hu, Xialin; Zhang, Zhen.
Afiliação
  • Zhu N; School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Zhu Y; School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Wang J; School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Gyimah E; School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China.
  • Hu X; Key Laboratory of Yangtze River Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China.
  • Zhang Z; School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China. Electronic address: zhangzhen@ujs.edu.cn.
Talanta ; 199: 72-79, 2019 Jul 01.
Article em En | MEDLINE | ID: mdl-30952318
ABSTRACT
A novel indirect competitive fluorescence immunoassay based on the quenching of I- to silver clusters (AgNCs) was developed for the highly selective and ultrasensitive detection of sulfamethazine (SMZ). In this system, alkaline phosphatase (ALP) was labeled on the secondary antibody (Ab2). And after a competition step, magnesium ascorbyl phosphate could be catalyzed to produce ascorbic acid under the catalysis of ALP. Subsequently, I2 was introduced and further reduced to I- in the presence of ascorbic acid, triggering the fluorescence quenching of AgNCs dispersed in isopropanol (IPA) buffer. More importantly, trace I- could lead to an obvious reduction in fluorescence signal, indicating the sensitivity of this method would be greatly improved. Under the optimal condition, this improved method for the SMZ detection has a lower detection of limit (LOD, 0.05000 µg/L) with a wider range (0.1400-71.71 µg/L). After an evaluation, the fluorescence ELISA proposed in this work has satisfactory accuracy and reliability (recoveries, 84.18-118.6%; CV, 2.03-7.64%), illustrating good performance and great potential for the detection of trace SMZ in environmental and biological samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Sulfametazina / Poluentes Químicos da Água / Ensaio de Imunoadsorção Enzimática / Monitoramento Ambiental / Fosfatase Alcalina / Fluorescência Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Sulfametazina / Poluentes Químicos da Água / Ensaio de Imunoadsorção Enzimática / Monitoramento Ambiental / Fosfatase Alcalina / Fluorescência Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article