Your browser doesn't support javascript.
loading
Non-Enzymatic Impedimetric Sensor Based on 3-Aminophenylboronic Acid Functionalized Screen-Printed Carbon Electrode for Highly Sensitive Glucose Detection.
Dorledo de Faria, Ricardo Adriano; Iden, Hassan; Heneine, Luiz Guilherme Dias; Matencio, Tulio; Messaddeq, Younès.
Afiliação
  • Dorledo de Faria RA; Department of Chemical Engineering, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Minas Gerais 30270-901, Brazil. ricardo.adriano08@hotmail.com.
  • Iden H; Center for Optics, Photonics and Lasers (COPL), Université Laval, Quebec City, QC G1V 0A6, Canada. ricardo.adriano08@hotmail.com.
  • Heneine LGD; Center for Optics, Photonics and Lasers (COPL), Université Laval, Quebec City, QC G1V 0A6, Canada. hassan.iden.1@ulaval.ca.
  • Matencio T; CDN Isotopes, Montreal, QC H9R 1H1, Canada. hassan.iden.1@ulaval.ca.
  • Messaddeq Y; Department of Applied Immunology, Fundação Ezequiel Dias (FUNED), Belo Horizonte, Minas Gerais 30510-010, Brazil. luiz.heneine@funed.mg.gov.br.
Sensors (Basel) ; 19(7)2019 Apr 09.
Article em En | MEDLINE | ID: mdl-30970595
ABSTRACT
A highly sensitive glucose sensor was prepared by a one-step method using 3-aminophenyl boronic acid as a unit of recognition and a screen-printed carbon electrode (SPCE) as an electrochemical transducer. Scanning Electron Microscopy confirmed the success of the functionalization of the SPCE due to the presence of clusters of boronic acid distributed on the carbon surface. In agreement with the Electrochemical Impedance Spectroscopy (EIS) tests performed before and after the functionalization, Cyclic Voltammetry results indicated that the electroactivity of the electrode decreased 37.9% owing to the presence of the poly phenylboronic acid on the electrode surface. EIS revealed that the sensor was capable to selectively detect glucose at a broad range of concentrations (limit of detection of 8.53 × 10-9 M), not recognizing fructose and sucrose. The device presented a stable impedimetric response when immediately prepared but suffered the influence of the storage time and some interfering species (dopamine, NaCl and animal serum). The response time at optimized conditions was estimated to be equal to 4.0 ± 0.6 s.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Borônicos / Técnicas Biossensoriais / Técnicas Eletroquímicas / Glucose Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Borônicos / Técnicas Biossensoriais / Técnicas Eletroquímicas / Glucose Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article