The values of shear wave elastography in avoiding repeat fine-needle aspiration for thyroid nodules with nondiagnostic and undetermined cytology.
Chen, Lin; Shi, Yi-Xin; Liu, Ying-Chun; Zhan, Jia; Diao, Xue-Hong; Chen, Yue; Zhan, Wei-Wei.
Afiliação
  • Chen L; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
  • Shi YX; Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University Medical School, Shanghai, China.
  • Liu YC; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
  • Zhan J; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
  • Diao XH; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
  • Chen Y; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
  • Zhan WW; Department of Ultrasound, Huadong Hospital, Fudan University, Shanghai, China.
Clin Endocrinol (Oxf) ; 91(1): 201-208, 2019 07.
Article em En | MEDLINE | ID: mdl-31004514
ABSTRACT

OBJECTIVE:

To evaluate the value of shear wave elastography (SWE) in avoiding repeat fine-needle aspiration of thyroid nodules with nondiagnostic and undetermined cytology.

METHODS:

A total of 232 thyroid nodules with nondiagnostic (n = 132) and undetermined (n = 100) cytology underwent ultrasound (US) and SWE, followed by repeat ultrasound (US)-guided fine-needle aspiration cytology (FNAC). The final diagnosis was based on cytological or pathological findings. The US and SWE characteristics of benign and malignant nodules were compared using the χ2 -test. The receiver operating characteristic (ROC) curves of the thyroid imaging reporting and data system (TI-RADS) categories from the US and the EMean and ESD from the SWE were graphed, and the areas under the curves (AUCs) were compared using a Z test.

RESULTS:

There were significant differences between the benign and malignant nodules in terms of the echogenicity, shape, margin, calcification and TI-RADS categories (all P < 0.05). The differences were significant between the malignant and benign nodules for EMean [(34.57 ± 14.81) kPa vs. (19.18 ± 7.09) kPa] and ESD [(13.68 ± 13.01) kPa vs. (3.97 ± 2.58) kPa] (both P < 0.001). Though the difference in the AUCs of EMean (0.864) and ESD (0.876) was not significant (P = 0.745), they both had higher diagnostic performances in comparison with TI-RADS categories (0.762) (all P < 0.05). Moreover, ESD attained a sensitivity of 100% with a relatively higher specificity of 49.75% when its cut-off value was 3.3 kPa.

CONCLUSIONS:

Shear wave elastography is a promising imaging method for reducing repeat FNAC for benign thyroid nodules with nondiagnostic and undetermined cytology when using ESD as an index.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândula Tireoide / Neoplasias da Glândula Tireoide / Nódulo da Glândula Tireoide / Biópsia por Agulha Fina / Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândula Tireoide / Neoplasias da Glândula Tireoide / Nódulo da Glândula Tireoide / Biópsia por Agulha Fina / Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article