Your browser doesn't support javascript.
loading
Implant insertion torque value in immediate loading: A retrospective study.
Del Giudice, R; Piattelli, A; Grande, N-M; Cataneo, E; Crispino, A; Petrini, M.
Afiliação
  • Del Giudice R; Department of Medical Oral and Biotechnological Sciences, University of Chieti - Italy, Address: Via Vestini 31, 66013 Chieti, Italy, petrini.morena@gmail.com.
Med Oral Patol Oral Cir Bucal ; 24(3): e398-e403, 2019 May 01.
Article em En | MEDLINE | ID: mdl-31011142
ABSTRACT

BACKGROUND:

The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. MATERIAL AND

METHODS:

In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV) > 32 Ncm (CG) and < 32 Ncm (LTG) and two different groups of equal sample size, 161 implants each, were distinguished. Crestal bone reabsorption, and the implant failure rate were evaluated after 2-years of follow-up.

RESULTS:

The bone reabsorption in LTG (0.49 ± 0.11 mm ) was significantly greater than CG (0.22 ± 0.04 mm), p<0.001. However, the survival rate after 2-years of follow-up was quite high and similar for both groups 96.89% for LTG and 97.52% for CG and no statistically significant differences have been found among the two groups for the implant failure rate (p=0.455).The Odds Ratio (OR) of implant failure was of 1.258 (95% CI 0.332, 4.772), but results were not statistical significant, p=0.740.

CONCLUSIONS:

The present study showed that although implants with ITV> 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Implantes Dentários para Um Único Dente / Carga Imediata em Implante Dentário Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Implantes Dentários para Um Único Dente / Carga Imediata em Implante Dentário Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article