Highly Sensitive Lab on a Chip (LOC) Immunoassay for Early Diagnosis of Respiratory Disease Caused by Respirable Crystalline Silica (RCS).
Upaassana, V Thiyagarajan; Ghosh, Sthitodhi; Chakraborty, Atreyee; Birch, M Eileen; Joseph, Pius; Han, Jungyoup; Ku, Bon Ki; Ahn, Chong H.
Afiliação
  • Upaassana VT; Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computer Science , University of Cincinnati , Cincinnati , Ohio 45221 , United States.
  • Ghosh S; Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computer Science , University of Cincinnati , Cincinnati , Ohio 45221 , United States.
  • Chakraborty A; Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computer Science , University of Cincinnati , Cincinnati , Ohio 45221 , United States.
  • Birch ME; Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH) , Division of Applied Research and Technology , 1090 Tusculum Avenue , Cincinnati , Ohio 45226 , United States.
  • Joseph P; Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH) , Health Effects Laboratory Division , 1095 Willowdale Road , Morgantown , West Virginia 26505 , United States.
  • Han J; Mico BioMed USA Inc. , 10999 Reed Hartman Highway , STE 309C, Cincinnati , Ohio 45242 , United States.
  • Ku BK; Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH) , Division of Applied Research and Technology , 1090 Tusculum Avenue , Cincinnati , Ohio 45226 , United States.
  • Ahn CH; Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computer Science , University of Cincinnati , Cincinnati , Ohio 45221 , United States.
Anal Chem ; 91(10): 6652-6660, 2019 05 21.
Article em En | MEDLINE | ID: mdl-31012299

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Silicose / Ensaio de Imunoadsorção Enzimática / Fator de Necrose Tumoral alfa / Dióxido de Silício / Técnicas Analíticas Microfluídicas / Dispositivos Lab-On-A-Chip Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Silicose / Ensaio de Imunoadsorção Enzimática / Fator de Necrose Tumoral alfa / Dióxido de Silício / Técnicas Analíticas Microfluídicas / Dispositivos Lab-On-A-Chip Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article