Chopper-modulated gas chromatography electroantennography enabled using high-temperature MEMS flow control device.
Zhou, Ming-Da; Akbar, Muhammad; Myrick, Andrew J; Xia, Yiqiu; Khan, Waleed J; Gao, Xiang; Baker, Thomas C; Zheng, Si-Yang.
Afiliação
  • Zhou MD; Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
  • Akbar M; Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA.
  • Myrick AJ; Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
  • Xia Y; Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA.
  • Khan WJ; Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
  • Gao X; Department of Entomology, The Pennsylvania State University, University Park, PA 16802, USA.
  • Baker TC; Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA.
  • Zheng SY; Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA.
Microsyst Nanoeng ; 3: 17062, 2017.
Article em En | MEDLINE | ID: mdl-31057886
We report the design, fabrication and characterization of a microelectromechanical systems (MEMS) flow control device for gas chromatography (GC) with the capability of sustaining high-temperature environments. We further demonstrate the use of this new device in a novel MEMS chopper-modulated gas chromatography-electroantennography (MEMS-GC-EAG) system to identify specific volatile organic compounds (VOCs) at extremely low concentrations. The device integrates four pneumatically actuated microvalves constructed via thermocompression bonding of the polyimide membrane between two glass substrates with microstructures. The overall size of the device is 32 mm×32 mm, and it is packaged in a 50 mm×50 mm aluminum housing that provides access to the fluidic connections and allows thermal control. The characterization reveals that each microvalve in the flow control chip provides an ON to OFF ratio as high as 1000:1. The device can operate reliably for more than 1 million switching cycles at a working temperature of 300 °C. Using the MEMS-GC-EAG system, we demonstrate the successful detection of cis-11-hexadecenal with a concentration as low as 1 pg at a demodulation frequency of 2 Hz by using an antenna harvested from the male Helicoverpa Virescens moth. In addition, 1 µg of a green leafy volatile (GLV) is barely detected using the conventional GC-EAG, while MEMS-GC-EAG can readily detect the same amount of GLV, with an improvement in the signal-to-noise ratio (SNR) of ~22 times. We expect that the flow control device presented in this report will allow researchers to explore new applications and make new discoveries in entomology and other fields that require high-temperature flow control at the microscale.