Impact of the repositionable Evolut R CoreValve system on the need for a permanent pacemaker after transcatheter aortic valve implantation in patients with severe aortic stenosis.
Ojeda, Soledad; Hidalgo, Francisco; Romero, Miguel; Mazuelos, Francisco; Suárez de Lezo, Javier; Martín, Ernesto; Lostalo, Adrián; Luque, Aurora; González, Rafael; Fernández, Ana; López-Aguilera, José; Segura, José; Guerrero, Noelia; Pan, Manuel.
Afiliação
  • Ojeda S; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Hidalgo F; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Romero M; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Mazuelos F; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Suárez de Lezo J; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Martín E; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Lostalo A; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Luque A; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • González R; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Fernández A; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • López-Aguilera J; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Segura J; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Guerrero N; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
  • Pan M; Division of Interventional Cardiology, Reina Sofia Hospital, University of Córdoba, Maimonides Institute for Research in Biomedicine of Córdoba (IMIBIC), Córdoba, Spain.
Catheter Cardiovasc Interv ; 95(4): 783-790, 2020 03 01.
Article em En | MEDLINE | ID: mdl-31062927
ABSTRACT

OBJECTIVES:

To compare the incidence of permanent pacemaker implantation (PPI) with the CoreValve and Evolut R prostheses, to evaluate the implantation depth with both types of prostheses, and to study factors predicting the need for PPI.

BACKGROUND:

The Evolut R CoreValve can be recaptured and repositioned during deployment, allowing a more precise implantation.

METHODS:

A total of 208 patients treated with CoreValve and 137 patients treated with Evolut R were analyzed. The depth of the prosthesis in the LVOT was measured by angiography in the annular perpendicular view projection after deploymen in all patients.

RESULTS:

Baseline conduction abnormalities were comparable between the groups (85/208, 40.9% vs. 53/137, 38.7%; p = 0.69). The mean prosthesis depth was 10.3 ± 8.6 mm in the CoreValve group and 5.5 ± 2.7 mm in the Evolut R group; p < 0.0001. Conduction disturbances after valve implantation were more frequent with the CoreValve (new-onset left bundle branch block 93, 44.7% vs. 16, 11.7%; p < 0.05, first-degree atrioventricular block 23, 11.1% vs. 5, 3.6%; p < 0.05). In addition, the incidence of PPI was significantly lower with Evolut R (45, 21.6% vs. 15, 10.9%; p = 0.01). The predictors of the need for PPI were the mean depth of the prosthesis (OR 1.13, 95% CI 1.06-1.21; p < 0.0001) and prior right bundle branch block (OR 10.22, 95% CI 4.62-22.63; p < 0.0001).

CONCLUSIONS:

The recapturable capability of the Evolut R system allowed for higher and precise valve implantation. This fact had an impact on the reduction in the need for PPI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Marca-Passo Artificial / Arritmias Cardíacas / Próteses Valvulares Cardíacas / Estimulação Cardíaca Artificial / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Marca-Passo Artificial / Arritmias Cardíacas / Próteses Valvulares Cardíacas / Estimulação Cardíaca Artificial / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article