Your browser doesn't support javascript.
loading
Readout-Segmented Echo-Planar DWI for the Detection of Cholesteatomas: Correlation with Surgical Validation.
Fischer, N; Schartinger, V H; Dejaco, D; Schmutzhard, J; Riechelmann, H; Plaikner, M; Henninger, B.
Afiliação
  • Fischer N; From the Departments of Otorhinolaryngology (N.F., V.H.S., D.D., J.S., H.R.).
  • Schartinger VH; From the Departments of Otorhinolaryngology (N.F., V.H.S., D.D., J.S., H.R.) Volker.Schartinger@i-med.ac.at.
  • Dejaco D; From the Departments of Otorhinolaryngology (N.F., V.H.S., D.D., J.S., H.R.).
  • Schmutzhard J; From the Departments of Otorhinolaryngology (N.F., V.H.S., D.D., J.S., H.R.).
  • Riechelmann H; From the Departments of Otorhinolaryngology (N.F., V.H.S., D.D., J.S., H.R.).
  • Plaikner M; Radiology (M.P., B.H.), Medical University of Innsbruck, Innsbruck, Austria.
  • Henninger B; Radiology (M.P., B.H.), Medical University of Innsbruck, Innsbruck, Austria.
AJNR Am J Neuroradiol ; 40(6): 1055-1059, 2019 06.
Article em En | MEDLINE | ID: mdl-31122917
ABSTRACT
BACKGROUND AND

PURPOSE:

MR imaging has become an important tool for the detection of cholesteatomas of the middle ear. Various diffusion-weighted imaging sequences are available and have shown promising results. This study aimed to evaluate readout-segmented echo-planar DWI for the detection of cholesteatoma and compare the results with surgical validation. MATERIALS AND

METHODS:

Fifty patients with chronic otitis media (24 females and 26 males; range, 12-76 years of age; mean age, 41 years) who underwent MR imaging before an operation of the middle ear (1-169 days) were included. The MR imaging protocol consisted of axial and coronal readout-segmented echo-planar DWI with b-values of 0 and 1000 s/mm2 and 3-mm slice thickness. The readout-segmented echo-planar diffusion-weighted images were fused with standard T2-weighted sequences for better anatomic assignment. The results of the MR imaging evaluation were correlated with the results from the operation.

RESULTS:

Readout-segmented echo-planar DWI detected 22 of the 25 cases of surgically proved cholesteatoma. It has an accuracy of 92% (95% confidence interval, 80.8%-97.8%), a sensitivity of 88%, a specificity of 96%, a positive predictive value of 96%, and a negative predictive value of 89%. In 1 case, a positive finding for cholesteatoma with readout-segmented echo-planar DWI could not be proved by histology, and in 3 cases, histology yielded a cholesteatoma that was not detected with MR imaging.

CONCLUSIONS:

Readout-segmented echo-planar DWI is a promising and reliable MR imaging sequence for the detection and exclusion of cholesteatoma.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Colesteatoma da Orelha Média / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Colesteatoma da Orelha Média / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article