Your browser doesn't support javascript.
loading
Accuracy of Different Apex Locators in Teeth with Simulated Apical Root Resorption: an In Vitro Study.
Jadhav, Ganesh Ranganath; Mittal, Priya; Patil, Vishal; Kandekar, Prashant; Kulkarni, Anish; Shinde, Siddharth; Syed, Shibli; Elahi, Saina.
Afiliação
  • Jadhav GR; Department of Conservative Dentistry and Endodontics, Sinhgad Dental College & Hospital, Pune, India.
  • Mittal P; Private Practitioner,Pune, India.
  • Patil V; Department of Conservative Dentistry and Endodontics, Aditya Dental College, Beed, India.
  • Kandekar P; Department of Oral and Maxillofacial Pathology, Ibn Sina National College for Medical Studies, Jeddah, India.
  • Kulkarni A; Private Practitioner,Pune, India.
  • Shinde S; Department of Orthodontics, BVDU Dental College and Hospital, Pune, India.
  • Syed S; Private Practitioner,Pune, India.
  • Elahi S; Department of Periodontology, MA Rangoonwala Dental College, Pune.
Folia Med (Plovdiv) ; 60(4): 624-631, 2018 Dec 01.
Article em En | MEDLINE | ID: mdl-31188764
BACKGROUND: Accurate working length (WL) determination is necessary in achieving optimal healing by non-surgical root canal therapy in teeth with inflammatory apical root resorption. Electronic apex locators (EALs) are one of the mainstays in determination of WL of teeth. AIM: This study evaluated the accuracy of three EALs [RootZX (third generation), iPex (fourth generation) and Raypex 6 (modification of a fifth generation)] in determining the WL of teeth with simulated apical root resorption in permanent teeth. MATERIALS AND METHODS: Forty freshly extracted maxillary anterior teeth were collected and a 45° oblique cut was made at the root apex with a disc to simulate apical root resorption. Actual working length (AWL) was determined by direct visual method and was used as a control. Electronic working length (EWL) values were measured by three different apex locators that are RootZX (Group I), iPex (Group II) and Raypex 6 (Group III) at apex, 0.5 mm and 1 mm from apex. All values obtained were tabulated and statistical evaluation was carried out. RESULTS: At apex, EWL obtained using iPex (p=0.05) showed a statistically significant difference from AWL. At 0.5 mm and 1.0 mm tolerance, iPex showed non-acceptability for WL measurement in 67.5% and 17.5% of samples compared to Root ZX (12.5% and 2.5%) and Raypex (7.5% and none) respectively. CONCLUSION: Within the limitation of this study, it can be concluded that Raypex 6 and RootZX show statistically significant accuracy in WL measurement compared with iPex in teeth with apical root resorption.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reabsorção da Raiz / Ápice Dentário Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reabsorção da Raiz / Ápice Dentário Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article