Your browser doesn't support javascript.
loading
Usefulness of the Transcatheter Aortic Valve Replacement Risk Score to Determine Mid-Term Outcomes.
Saji, Mike; Tobaru, Tetsuya; Higuchi, Ryosuke; Mahara, Keitaro; Takamisawa, Itaru; Iguchi, Nobuo; Doi, Shinichiro; Okazaki, Shinya; Tamura, Harutoshi; Takanashi, Shuichiro; Takayama, Morimasa; Isobe, Mitsuaki.
Afiliação
  • Saji M; Department of Cardiology, Sakakibara Heart Institute.
  • Tobaru T; Department of Cardiology, Sakakibara Heart Institute.
  • Higuchi R; Department of Cardiology, Sakakibara Heart Institute.
  • Mahara K; Department of Cardiology, Sakakibara Heart Institute.
  • Takamisawa I; Department of Cardiology, Sakakibara Heart Institute.
  • Iguchi N; Department of Cardiology, Sakakibara Heart Institute.
  • Doi S; Department of Cardiovascular Medicine, Juntendo University School of Medicine.
  • Okazaki S; Department of Cardiovascular Medicine, Juntendo University School of Medicine.
  • Tamura H; Department of Cardiology, Pulmonology and Nephrology, Yamagata University School of Medicine.
  • Takanashi S; Department of Cardiovascular Surgery, Sakakibara Heart Institute.
  • Takayama M; Department of Cardiology, Sakakibara Heart Institute.
  • Isobe M; Department of Cardiology, Sakakibara Heart Institute.
Circ J ; 83(8): 1755-1761, 2019 07 25.
Article em En | MEDLINE | ID: mdl-31189752
ABSTRACT

BACKGROUND:

The purpose of this study was to investigate if the transcatheter aortic valve replacement (TAVR) risk score can independently predict outcomes following TAVR, and to evaluate its predictive performance.Methods and 

Results:

This retrospective multicenter study comprised 682 patients with severe aortic stenosis who underwent TAVR. The primary endpoint was all-cause death following TAVR. The clinical model was established using variables identified as independent predictors in the multivariate analysis. Incremental values were assessed after adding atrial fibrillation, body mass index (BMI), and serum albumin to the TAVR risk score in receiver-operating characteristic analysis. The median TAVR risk score was 2.1% with a mean follow-up of 505 days. On Kaplan-Meier analysis, a TAVR risk score >4% had lowest survival rate, whereas TAVR risk score ≤2% had the highest survival rate at 3 years (log-rank P<0.001). The multivariate Cox regression analysis found the TAVR risk score was independently associated with all-cause death, and demonstrated moderate predictive performance for predicting all-cause death at 3 years. However, if each independent predictor is added to the model, it significantly increased discriminatory performance, particularly with BMI and serum albumin level.

CONCLUSIONS:

We demonstrated that the TAVR risk score could independently predict mid-term death following TAVR, and had greater predictive performance for predicting all-cause death at 3 years with BMI and serum albumin level.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Técnicas de Apoio para a Decisão / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Técnicas de Apoio para a Decisão / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article