Your browser doesn't support javascript.
loading
Monolithic CAD-CAM lithium disilicate versus monolithic CAD-CAM zirconia for single implant-supported posterior crowns using a digital workflow: A 3-year cross-sectional retrospective study.
De Angelis, Paolo; Passarelli, Pier Carmine; Gasparini, Giulio; Boniello, Roberto; D'Amato, Giuseppe; De Angelis, Silvio.
Afiliação
  • De Angelis P; Oral Surgery Resident, Department of Oral and Maxillofacial Surgery, Catholic University of the Sacred Heart Medical School, Rome, Italy. Electronic address: dr.paolodeangelis@gmail.com.
  • Passarelli PC; Oral Surgery Resident, Department of Oral Surgery, Catholic University of the Sacred Heart Medical School, Rome, Italy.
  • Gasparini G; Professor, Department of Oral and Maxillofacial Surgery, Catholic University of the Sacred Heart Medical School, Rome, Italy.
  • Boniello R; Attending Physician, Department of Oral and Maxillofacial Surgery, Catholic University of the Sacred Heart Medical School, Rome, Italy.
  • D'Amato G; Attending Physician, Department of Oral and Maxillofacial Surgery, Catholic University of the Sacred Heart Medical School, Rome, Italy.
  • De Angelis S; Private practice, Ascoli Piceno, Italy.
J Prosthet Dent ; 123(2): 252-256, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31202552
ABSTRACT
STATEMENT OF

PROBLEM:

Dentistry has evolved significantly with the introduction of digital technologies and materials; however, clinical evidence for the performance of the complete digital workflow for single implant-supported posterior crowns is lacking.

PURPOSE:

The purpose of this cross-sectional retrospective clinical study was to compare the clinical outcomes of 2 types of implant-supported crown used to replace a single missing posterior tooth in a completely digital workflow transocclusal screw-retained monolithic lithium disilicate crowns versus transocclusal screw-retained monolithic zirconia crowns. MATERIAL AND

METHODS:

A total of 38 participants who had been provided with dental implants and transocclusal screw-retained monolithic lithium disilicate or zirconia single crowns were evaluated in the study. Clinical and esthetic outcomes were recorded after a 3-year follow-up.

RESULTS:

Both groups had comparable clinical outcomes with a survival rate of 100%. In the lithium disilicate group, 89% of the participants were free of technical complications, and 95%, in the zirconia group. Only 1 patient experienced minor chipping affecting a lithium disilicate crown. All complications were considered minor and were easily resolved, and none of the participants required replacement of a crown. No biological complications were recorded in either group.

CONCLUSIONS:

Within the limitations of this cross-sectional retrospective clinical study, monolithic lithium disilicate and zirconia screw-retained single crowns fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) and a fully digital workflow were found to be reliable and suitable clinical options for restoring a posterior missing tooth on a dental implant.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Fluxo de Trabalho Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Fluxo de Trabalho Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article