Your browser doesn't support javascript.
loading
Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers.
Quesada-González, Daniel; Stefani, Christina; González, Israel; de la Escosura-Muñiz, Alfredo; Domingo, Neus; Mutjé, Pere; Merkoçi, Arben.
Afiliação
  • Quesada-González D; Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain.
  • Stefani C; Advanced Atomic Force Microscopy Laboratory, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain.
  • González I; LEPAMAP Research Group, University of Girona, C/Maria Aurèlia Capmany, 61, 17071, Girona, Spain.
  • de la Escosura-Muñiz A; Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain.
  • Domingo N; Advanced Atomic Force Microscopy Laboratory, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain.
  • Mutjé P; LEPAMAP Research Group, University of Girona, C/Maria Aurèlia Capmany, 61, 17071, Girona, Spain.
  • Merkoçi A; Nanobioelectronics & Biosensors Group, Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193, Barcelona, Spain; ICREA, Institució Catalana de Recerca I Estudis Avançats, Pg. Lluís Companys 23, 08010, Barcelona, Spain. Electronic address: arben.m
Biosens Bioelectron ; 141: 111407, 2019 Sep 15.
Article em En | MEDLINE | ID: mdl-31207571
ABSTRACT
Lateral flow paper-based biosensors merge as powerful tools in point-of-care diagnostics since they are cheap, portable, robust, selective, fast and easy to use. However, the sensitivity of this type of biosensors is not always as high as required, often not permitting a clear quantification. To improve the colorimetric response of standard lateral flow strips (LFs), we have applied a new enhancement strategy that increases the sensitivity of LFs based on the use of cellulose nanofibers (CNF). CNF penetrate inside the pores of LFs nitrocellulose paper, compacting the pore size only in the test line, particularly near the surface of the strip. This modification retains the bioreceptors (antibodies) close to the surface of the strips, and thus further increasing the density of selectively attached gold nanoparticles (AuNPs) in the top part of the membrane, in the test line area, only when the sample is positive. This effect boosts in average a 36.6% the sensitivity of the LFs. The optical measurements of the LFs were carried out with a mobile phone camera whose imaging resolution was improved by attaching microscopic lens on the camera objective. The characterization of CNF into paper and their effect was analyzed using atomic force microscope (AFM) and scanning electron microscope (SEM) imaging techniques.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Celulose / Nanopartículas Metálicas / Nanofibras / Ouro Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Celulose / Nanopartículas Metálicas / Nanofibras / Ouro Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article