Your browser doesn't support javascript.
loading
Fine-needle aspiration of cutaneous, subcutaneous, and intracavitary masses in dogs and cats using 22- vs 25-gauge needles.
Arai, Shiori; Rist, Paul; Clancey, Noel; Gilroy, Cornelia; Stryhn, Henrik; Amsellem, Pierre.
Afiliação
  • Arai S; Department of Companion Animals, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
  • Rist P; Department of Companion Animals, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
  • Clancey N; Department of Pathology and Microbiology, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
  • Gilroy C; Department of Pathology and Microbiology, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
  • Stryhn H; Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
  • Amsellem P; Department of Companion Animals, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, PE, Canada.
Vet Clin Pathol ; 48(2): 287-292, 2019 Jun.
Article em En | MEDLINE | ID: mdl-31210389
ABSTRACT

BACKGROUND:

Fine-needle aspiration (FNA) is a common procedure as a diagnostic tool in veterinary medicine. However, it is unclear whether the gauge of the needle affects the quality of cytology.

OBJECTIVE:

This study compared the quality of cytologic samples obtained via FNA using 22- or 25-gauge needles.

METHODS:

Fine-needle aspiration was performed on 50 masses (cutaneous, subcutaneous, or intracavitary) obtained from client-owned animals. The size of the needle was randomly assigned using either of the following two sequences 22-25-22 gauge or 25-22-25 gauge. Samples were evaluated by two board-certified clinical pathologists to assess cellularity, blood contamination, amount of cellular debris, degree of cellular trauma, and the overall ability to make a diagnosis for each sample.

RESULTS:

No significant difference was detected between the 22- and 25-gauge needle samples for cellularity, whereas a significant difference was present for blood contamination, amount of cellular debris, and degree of cellular trauma. The overall ability to make a diagnosis was not significantly affected by the needle gauge. The degree of cellular trauma was significantly increased in intracavitary samples. CONCLUSIONS AND CLINICAL RELEVANCE Needle gauge is a contributing factor to FNA sample quality. However, it did not affect the overall ability to make a diagnosis. Samples obtained using 25-gauge needles resulted in less blood contamination yet increased cellular trauma compared to 22-gauge needle samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article