Your browser doesn't support javascript.
loading
Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks.
Asenbaum, Ulrika; Schoder, Maria; Schwartz, Ernst; Langs, Georg; Baltzer, Pascal; Wolf, Florian; Prusa, Alexander M; Loewe, Christian; Nolz, Richard.
Afiliação
  • Asenbaum U; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
  • Schoder M; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
  • Schwartz E; Computational and Imaging Research Laboratory, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Langs G; Computational and Imaging Research Laboratory, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Baltzer P; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
  • Wolf F; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
  • Prusa AM; Department of Surgery, Medical University of Vienna, Vienna, Austria.
  • Loewe C; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
  • Nolz R; Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria. richard.nolz@meduniwien.ac.at.
Eur Radiol ; 29(12): 6385-6395, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31250169
OBJECTIVES: To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS: In this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively. RESULTS: Stent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p = 0.017), proximal neck diameter ([HR] 5.07; p < 0.001), infrarenal aortic neck angulation ([HR] 1.02, p = 0.002), and proximal neck length ([HR] 0.62, p < 0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p < 0.001, p = 0.022). CONCLUSIONS: Age, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position. KEY POINTS: • Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations. • Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks. • Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Endoleak Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article