Your browser doesn't support javascript.
loading
Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma.
Si-Mohamed, Salim; Dupuis, Nicolas; Tatard-Leitman, Valérie; Rotzinger, David; Boccalini, Sara; Dion, Matthias; Vlassenbroek, Alain; Coulon, Philippe; Yagil, Yoad; Shapira, Nadav; Douek, Philippe; Boussel, Loic.
Afiliação
  • Si-Mohamed S; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Lyon, France. salimaymeric@gmail.com.
  • Dupuis N; Radiology Department, Hospices Civils de Lyon, CHU Louis Pradel, 59 Boulevard Pinel, 69500, Bron, France. salimaymeric@gmail.com.
  • Tatard-Leitman V; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Lyon, France.
  • Rotzinger D; Radiology Department, Hospices Civils de Lyon, CHU Louis Pradel, 59 Boulevard Pinel, 69500, Bron, France.
  • Boccalini S; Anatomy Lab, Rockefeller Faculty, Lyon Est, Lyon, France.
  • Dion M; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Lyon, France.
  • Vlassenbroek A; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital , Lausanne, Switzerland.
  • Coulon P; Radiology Department, Hospices Civils de Lyon, CHU Louis Pradel, 59 Boulevard Pinel, 69500, Bron, France.
  • Yagil Y; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, Lyon, France.
  • Shapira N; Radiology Department, Hospices Civils de Lyon, CHU Louis Pradel, 59 Boulevard Pinel, 69500, Bron, France.
  • Douek P; Anatomy Lab, Rockefeller Faculty, Lyon Est, Lyon, France.
  • Boussel L; CT Clinical Science, Best, Netherlands.
Eur Radiol ; 29(12): 6762-6771, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31264015
ABSTRACT

PURPOSE:

To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies. MATERIALS AND

METHODS:

Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 ± 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated.

RESULTS:

In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 ± 0.7, TNC = 3.1 ± 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%.

CONCLUSION:

DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality. KEY POINTS • Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. • Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. • Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Tomografia Computadorizada por Raios X / Hematoma Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Qualitative_research Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Aorta / Tomografia Computadorizada por Raios X / Hematoma Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Qualitative_research Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article