Your browser doesn't support javascript.
loading
Safety and efficacy of tacrolimus-coated silicone plates as an alternative to mitomycin C in a rabbit model of conjunctival fibrosis.
Yoon, Sam Young; Kim, Eun-Soon; Han, Gill Sang; Suh, Leejee H; Jung, Hyun Suk; Tchah, Hungwon; Kim, Jae Yong.
Afiliação
  • Yoon SY; Department of Ophthalmology, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Republic of Korea.
  • Kim ES; Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York, United States of America.
  • Han GS; Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
  • Suh LH; School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
  • Jung HS; Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York, United States of America.
  • Tchah H; School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
  • Kim JY; Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
PLoS One ; 14(7): e0219194, 2019.
Article em En | MEDLINE | ID: mdl-31276522
ABSTRACT

PURPOSE:

To find safer and more effective drugs than mitomycin C to prevent conjunctival fibrosis in a rabbit model.

METHODS:

Twenty-four rabbits were involved and randomly divided into four groups. Limbus-based peritomy was performed at the superior cornea, and normal saline (NS group), mitomycin C (MMC group), SR (SR group), or TC (TC group)-coated silicone plate was inserted at the sub-Tenon's space in each group. Conjunctival congestion was evaluated at 1 and 4 weeks postoperatively. At 4 weeks, the numbers of inflammatory cells, fibroblasts, myofibroblasts, blood vessels, and goblet cells were counted in the conjunctiva and Tenon's capsule around the silicone plate.

RESULTS:

At 4 weeks, conjunctival congestion was significantly less than that observed at 1 week in the SR and TC groups (p < 0.05), whereas the number of myofibroblasts was significantly lower in the MMC and TC groups (p < 0.05). The conjunctiva was significantly less congested in the TC group versus the other groups at 1 week and 4 weeks (p < 0.05). The TC group had the lowest number of inflammatory cells and MMC group had the lowest number of goblet cells among all groups (p < 0.05).

CONCLUSIONS:

The TC-coated silicone plate was more effective in inhibiting inflammation and fibrosis versus the MMC-coated silicone plate and was associated with fewer adverse effects in the rabbit model.