Your browser doesn't support javascript.
loading
Shear Behaviors of RC Beams Externally Strengthened with Engineered Cementitious Composite Layers.
Wang, Guan; Yang, Caiqian; Pan, Yong; Zhu, Fawang; Jin, Kai; Li, Kefeng; Nanni, Antonio.
Afiliação
  • Wang G; Key Laboratory of Concrete & Pre-stressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 211189, China.
  • Yang C; Department of Civil, Architectural, and Environmental Engineering, University of Miami, Miami, FL 33146, USA.
  • Pan Y; Key Laboratory of Concrete & Pre-stressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 211189, China. ycqjxx@seu.edu.cn.
  • Zhu F; College of Civil Engineering and Mechanics, Xiangtan University, Xiangtan 411105, China. ycqjxx@seu.edu.cn.
  • Jin K; Jiangsu Eastern Expressway Management Co., Ltd., Yancheng 224000, China.
  • Li K; Key Laboratory of Concrete & Pre-stressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 211189, China.
  • Nanni A; Key Laboratory of Concrete & Pre-stressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 211189, China.
Materials (Basel) ; 12(13)2019 Jul 05.
Article em En | MEDLINE | ID: mdl-31284446
ABSTRACT
The shear behaviors of reinforced concrete (RC) beams externally strengthened with engineered cementitious composite (ECC) layers were studied and the strengthening effect was evaluated based on a truss and arch model. The beams were designed without web reinforcement in the middle part and ECC was sprayed onto both sides of the beams to the designed thicknesses, which were 20 mm and 40 mm. A series of four-point bending experiments were conducted and analyzed. The development of the shear strain in each side of the beams was recorded by strain rosettes formed with three fiber Bragg grating (FBG) sensors. The thickness of ECC layers, reinforcement ratios, and shear span-to-depth ratios were considered and analyzed. This is an effective way to shear strengthen RC beams with ECC layers. The ultimate load of the strengthened specimen can be improved by 89% over the control specimen. Strengthening an RC beam into an under-reinforced beam should be avoided. The FBG sensors are suitable to measure and monitor the development of shear strain in the side of the strengthened specimen. Based on the truss and arch model, an evaluation of the shear strengthening effect was established and the results agree well with the experimental results.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article