Analysis of a multicentre cloud-based CT dosimetric database: preliminary results.
Calderoni, Francesca; Campanaro, Federica; Colombo, Paola Enrica; Campoleoni, Mauro; De Mattia, Cristina; Rottoli, Federica; Galetta, Giannicola; Zucconi, Fabio; Pola, Andrea; Righini, Andrea; Triulzi, Fabio; Vanzulli, Angelo; Torresin, Alberto.
Afiliação
  • Calderoni F; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
  • Campanaro F; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
  • Colombo PE; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
  • Campoleoni M; Medical Physics Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Pace 9, 20122, Milan, Italy.
  • De Mattia C; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
  • Rottoli F; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
  • Galetta G; Medical Physics, ASST Fatebenefratelli Sacco, via G.B. Grassi 74, 20157, Milan, Italy.
  • Zucconi F; Medical Physics, ASST Fatebenefratelli Sacco, via G.B. Grassi 74, 20157, Milan, Italy.
  • Pola A; Department of Energy, Politecnico di Milano, via La Masa 34, 20156, Milan, Italy.
  • Righini A; Pediatric Radiology and Neuroradiology Unit, Children's Hospital V. Buzzi, Via Castelvetro 32, 20154, Milan, Italy.
  • Triulzi F; Department of Neuroradiology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Via Pace 9, 20122, Milan, Italy.
  • Vanzulli A; Department of Radiology, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy. angelo.vanzulli@ospedaleniguarda.it.
  • Torresin A; Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162, Milan, Italy.
Eur Radiol Exp ; 3(1): 27, 2019 07 16.
Article em En | MEDLINE | ID: mdl-31309360
BACKGROUND: To manage and analyse dosimetric data provided by computed tomography (CT) scanners from four Italian hospitals. METHODS: A radiation dose index monitoring (RDIM) software was used to collect anonymised exams stored in a cloud server. Since hospitals use different names for the same procedure, digital imaging and communications in medicine (DICOM) tags more appropriate to describe exams were selected and associated to study common names (SCNs) from a radiology playbook according to scan region and use of contrast media. Retrospective analysis was carried out to describe population and to evaluate dosimetric indexes and inaccuracies associated with SCNs. RESULTS: More than 400 procedures were clustered into 95 SCNs, but 78% of exams on adults were described with only 10 SCNs. Median values of dose-length product (DLP) and volumetric CT dose index (CTDIvol) for three analysed SCNs were in agreement with those previously published. The percentage of inaccuracies does not heavily affect the dosimetric analysis on the whole cloud, since variations in median values reached at most 8%. CONCLUSIONS: Implementation of a cloud-based RDIM software and related issues were described, showing the strength of the chosen playbook-based clustering and its usefulness for homogeneous data analysis. This approach may allow for optimisation actions, accurate assessment of the risk associated with radiation exposure, comparison of different facilities, and, last but not least, collection of information for the implementation of the 2013/59 Euratom Directive.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Bases de Dados Factuais / Computação em Nuvem Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Bases de Dados Factuais / Computação em Nuvem Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2019 Tipo de documento: Article