Your browser doesn't support javascript.
loading
Application of high expansion degradable cotton in nasal bleeding model of dog.
Zhong, Bing; Liu, Feng; Yang, Feng-Juan; Wu, Chun-Shu; Du, Jin-Tao; Liu, Shi-Xi.
Afiliação
  • Zhong B; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China.
  • Liu F; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China. lfdoctorent@outlook.com.
  • Yang FJ; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China.
  • Wu CS; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China.
  • Du JT; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China.
  • Liu SX; Department of Otolaryngology Head and Neck Surgery, West China Hospital of Sichuan University, 37Guoxue Lane, Chengdu, 610041, Sichuan Province, China.
Eur Arch Otorhinolaryngol ; 276(10): 2819-2826, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31332548
ABSTRACT

BACKGROUND:

The discomfort and complications have always been problems for nasal packing materials. This study provided a new nasal packing material called high expansion degradable cotton (HEDC).

METHODS:

Nasal endoscopic surgery was used to establish a dog model of nasal bleeding, and wound surfaces were filled with Merocel, Nasopore and HEDC, respectively. Intraoperative and postoperative bleeding of 24 h was calculated. We evaluate the absorbability score, adhesion score, infection sore and nasal mucosal epithelium in postoperative 3, 7, 14 and 28 days. HE staining and electron microscopy were used to evaluate the recovery of nasal mucosa.

RESULTS:

There was no significant difference in nasal bleeding between HEDC, Merocel and Nasopore. Nasal endoscopic examination revealed HEDC absorbability of score, adhesion score, infection score were significantly lower than Merocel and Nasopore. The epithelialization time of HEDC was significantly shorter than that of Merocel and Nasopore. HE staining showed that HEDC and Nasopore could significantly reduce scar hyperplasia on the wound surface. The results of electron microscopy suggested that HEDC could protect the edge cilia of the wound.

CONCLUSION:

HEDC could be used as new choice for hemostasis after nasal endoscopic surgery, which could reduce nasal epithelialization time, and protect wound edge cilia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Álcool de Polivinil / Epistaxe / Hemorragia Pós-Operatória / Cirurgia Endoscópica por Orifício Natural / Procedimentos Cirúrgicos Nasais / Formaldeído Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Álcool de Polivinil / Epistaxe / Hemorragia Pós-Operatória / Cirurgia Endoscópica por Orifício Natural / Procedimentos Cirúrgicos Nasais / Formaldeído Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article