Your browser doesn't support javascript.
loading
Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.
Kim, D; Heo, Y J; Jeong, H W; Baek, J W; Han, J-Y; Lee, J Y; Jin, S-C; Baek, H J.
Afiliação
  • Kim D; From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.).
  • Heo YJ; From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.) youngjin726@hanmail.net.
  • Jeong HW; From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.).
  • Baek JW; From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.).
  • Han JY; From the Departments of Radiology (D.K., Y.J.H., H.W.J., J.W.B., J.-Y.H.).
  • Lee JY; Internal Medicine (J.Y.L.), Inje University Busan Paik Hospital, Busan, Korea.
  • Jin SC; Department of Neurosurgery (S.-C.J.), Inje University Haeundae Paik Hospital, Busan, Republic of Korea.
  • Baek HJ; Department of Radiology (H.J.B.), Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Republic of Korea.
AJNR Am J Neuroradiol ; 40(9): 1469-1475, 2019 09.
Article em En | MEDLINE | ID: mdl-31371358
ABSTRACT
BACKGROUND AND

PURPOSE:

Contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) with the delay alternating with nutation for tailored excitation (DANTE) pulse could suppress the blood flow signal and provide a higher contrast-to-noise ratio of enhancing lesion-to-brain parenchyma than the MPRAGE sequence. The purpose of our study was to evaluate the usefulness of SPACE with DANTE compared with MPRAGE for detecting brain metastases. MATERIALS AND

METHODS:

Seventy-one patients who underwent contrast-enhanced SPACE with DANTE and MPRAGE sequences and who were suspected of having metastatic lesions were included. Two neuroradiologists determined the number of enhancing lesions, and diagnostic performance was evaluated using figure of merit, sensitivity, positive predictive value, interobserver agreement, and reading time. Contrast-to-noise ratiolesion/parenchyma and contrast-to-noise ratiowhite matter/gray matter were also assessed.

RESULTS:

SPACE with DANTE (observer one, 328; observer two, 324) revealed significantly more small (<5 mm) enhancing lesions than MPRAGE (observer one, 175; observer two, 150) (P < 0.001 for observer 1, P ≤ .0001 for observer 2). Furthermore, SPACE with DANTE showed significantly higher figure of merit and sensitivity and shorter reading time than MPRAGE for both observers. The mean contrast-to-noise ratiolesion/parenchyma of SPACE with DANTE (52.3 ± 43.1) was significantly higher than that of MPRAGE (17.5 ± 19.3) (P ≤ .0001), but the mean contrast-to-noise ratiowhite matter/gray matter of SPACE with DANTE (-0.65 ± 1.39) was significantly lower than that of MPRAGE (3.08 ± 1.39) (P ≤ .0001).

CONCLUSIONS:

Compared with MPRAGE, SPACE with DANTE significantly improves the detection of brain metastases.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article