Ultrasound-Guided Umbilical Venous Catheter Insertion With Alignment of the Umbilical Vein and Ductus Venosus.
J Ultrasound Med
; 39(2): 379-383, 2020 Feb.
Article
em En
| MEDLINE
| ID: mdl-31400014
Previous studies have highlighted the importance of confirming the position of an umbilical venous catheter (UVC) tip by an ultrasound (US) examination. However, methods for preventing insertion into the portal circulation under US guidance have not yet been established. We report 15 cases in which a UVC was successfully passed through the ductus venosus by compressing the upper abdomen near the portal sinus of the liver to align the umbilical vein and ductus venosus under US guidance. The UVC was inserted into the correct position in 14 of the 15 neonates (93%) without complications.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Veias Umbilicais
/
Cateterismo
/
Ultrassonografia de Intervenção
Limite:
Female
/
Humans
/
Male
/
Newborn
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article