Your browser doesn't support javascript.
loading
Transfer of a Multiclass Method for over 60 Antibiotics in Food from High Resolution to Low Resolution Mass Spectrometry.
Giusepponi, Danilo; Paoletti, Fabiola; Barola, Carolina; Moretti, Simone; Saluti, Giorgio; Ianni, Federica; Sardella, Roccaldo; Galarini, Roberta.
Afiliação
  • Giusepponi D; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy.
  • Paoletti F; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy.
  • Barola C; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy.
  • Moretti S; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy.
  • Saluti G; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy.
  • Ianni F; Department of Pharmaceutical Sciences, University of Perugia, 06123 Perugia, Italy.
  • Sardella R; Department of Pharmaceutical Sciences, University of Perugia, 06123 Perugia, Italy.
  • Galarini R; Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", 06126 Perugia, Italy. r.galarini@izsum.it.
Molecules ; 24(16)2019 Aug 13.
Article em En | MEDLINE | ID: mdl-31412663
ABSTRACT
A multiclass method has been developed to screen and confirm a wide range of anti-microbial residues in muscle and milk, and validated using liquid-chromatography coupled to (low-resolution, LR) tandem mass spectrometry (LC-QqQ). Over sixty antibiotics, belonging to ten distinct families, were included in the method scope. The development process was rapidly concluded as a result of two previously implemented methods. This consisted of identical sample treatments, followed by liquid chromatography, and coupled with high-resolution (HR) mass spectrometry (LC-Q-Orbitrap). The validation study was performed in the range between 10-1500 µg·kg-1 for muscles and 2-333 µg·kg-1 for milk. The main performance characteristics were estimated and, then, compared to those previously obtained with HR technique. The validity of the method transfer was ascertained also through inter-laboratory studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Drogas / Análise de Alimentos / Antibacterianos Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Drogas / Análise de Alimentos / Antibacterianos Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article