Your browser doesn't support javascript.
loading
Quantitative and Qualitative Comparison of 4D-DSA with 3D-DSA Using Computational Fluid Dynamics Simulations in Cerebral Aneurysms.
Lang, S; Hoelter, P; Birkhold, A I; Schmidt, M; Endres, J; Strother, C; Doerfler, A; Luecking, H.
Afiliação
  • Lang S; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany Stefan.Lang3@uk-erlangen.de.
  • Hoelter P; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany.
  • Birkhold AI; Siemens Healthcare GmbH (A.I.B.), Erlangen, Germany.
  • Schmidt M; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany.
  • Endres J; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany.
  • Strother C; Department of Radiology (C.S.), Clinical Sciences Center, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Doerfler A; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany.
  • Luecking H; From the Department of Neuroradiology (S.L., P.H., M.S., J.E., A.D., H.L.), University of Erlangen-Nuremberg, Erlangen, Germany.
AJNR Am J Neuroradiol ; 40(9): 1505-1510, 2019 09.
Article em En | MEDLINE | ID: mdl-31467234
ABSTRACT
BACKGROUND AND

PURPOSE:

4D-DSA allows time-resolved 3D imaging of the cerebral vasculature. The aim of our study was to evaluate this method in comparison with the current criterion standard 3D-DSA by qualitative and quantitative means using computational fluid dynamics. MATERIALS AND

METHODS:

3D- and 4D-DSA datasets were acquired in patients with cerebral aneurysms. Computational fluid dynamics analysis was performed for all datasets. Using computational fluid dynamics, we compared 4D-DSA with 3D-DSA in terms of both aneurysmal geometry (quantitative maximum diameter, ostium size [OZ1/2], volume) and hemodynamic parameters (qualitative flow stability, flow complexity, inflow concentration; quantitative average/maximum wall shear stress, impingement zone, low-stress zone, intra-aneurysmal pressure, and flow velocity). Qualitative parameters were descriptively analyzed. Correlation coefficients (r, P value) were calculated for quantitative parameters.

RESULTS:

3D- and 4D-DSA datasets of 10 cerebral aneurysms in 10 patients were postprocessed. Evaluation of aneurysmal geometry with 4D-DSA (r maximum diameter = 0.98, P maximum diameter <.001; r OZ1/OZ2 = 0.98/0.86, P OZ1/OZ2 < .001/.002; r volume = 0.98, P volume <.001) correlated highly with 3D-DSA. Evaluation of qualitative hemodynamic parameters (flow stability, flow complexity, inflow concentration) did show complete accordance, and evaluation of quantitative hemodynamic parameters (r average/maximum wall shear stress diastole = 0.92/0.88, P average/maximum wall shear stress diastole < .001/.001; r average/maximum wall shear stress systole = 0.94/0.93, P average/maximum wall shear stress systole < .001/.001; r impingement zone = 0.96, P impingement zone < .001; r low-stress zone = 1.00, P low-stress zone = .01; r pressure diastole = 0.84, P pressure diastole = .002; r pressure systole = 0.9, P pressure systole < .001; r flow velocity diastole = 0.95, P flow velocity diastole < .001; r flow velocity systole = 0.93, P flow velocity systole < .001) did show nearly complete accordance between 4D- and 3D-DSA.

CONCLUSIONS:

Despite a different injection protocol, 4D-DSA is a reliable basis for computational fluid dynamics analysis of the intracranial vasculature and provides equivalent visualization of aneurysm geometry compared with 3D-DSA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Digital / Aneurisma Intracraniano / Hidrodinâmica / Neuroimagem Tipo de estudo: Qualitative_research Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Digital / Aneurisma Intracraniano / Hidrodinâmica / Neuroimagem Tipo de estudo: Qualitative_research Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article