Your browser doesn't support javascript.
loading
Characterization of a multianalyte GC-MS/MS procedure for detecting and quantifying polycyclic aromatic hydrocarbons (PAHs) and PAH derivatives from air particulate matter for an improved risk assessment.
Mueller, Andrea; Ulrich, Nadin; Hollmann, Josef; Zapata Sanchez, Carmen E; Rolle-Kampczyk, Ulrike E; von Bergen, Martin.
Afiliação
  • Mueller A; Helmholtz Centre for Environmental Research GmbH - UFZ, Dep. of Molecular Systems Biology, Permoserstr. 15, 04318 Leipzig, Germany. Electronic address: a.mueller@ufz.de.
  • Ulrich N; Helmholtz Centre for Environmental Research GmbH - UFZ, Dep. of Analytical Environmental Chemistry, Permoserstr. 15, 04318 Leipzig, Germany.
  • Hollmann J; Helmholtz Centre for Environmental Research GmbH - UFZ, Dep. of Molecular Systems Biology, Permoserstr. 15, 04318 Leipzig, Germany.
  • Zapata Sanchez CE; Universidad Nacional de Colombia, Sede Medellin, Facultad de Minas, Departamento de Geociencias y Medioambiente, Carrera 80 Nr 65-223, Bl M3, Calaire, 050041 Medellin, Colombia.
  • Rolle-Kampczyk UE; Helmholtz Centre for Environmental Research GmbH - UFZ, Dep. of Molecular Systems Biology, Permoserstr. 15, 04318 Leipzig, Germany.
  • von Bergen M; Helmholtz Centre for Environmental Research GmbH - UFZ, Dep. of Molecular Systems Biology, Permoserstr. 15, 04318 Leipzig, Germany; University of Leipzig, Faculty of Life Sciences, Institute of Biochemistry, Talstr. 33, 04103 Leipzig, Germany.
Environ Pollut ; 255(Pt 2): 112967, 2019 Dec.
Article em En | MEDLINE | ID: mdl-31610516
A correct description of the concentration and distribution of particle bound polycyclic aromatic hydrocarbons is important for risk assessment of atmospheric particulate matter. A new targeted GC-MS/MS method was developed for analyzing 64 PAHs including compounds with a molecular weight >300, as well as nitro-, methyl-, oxy- and hydroxyl derivatives in a single analysis. The instrumental LOD ranged between 0.03 and 0.7 pg/µL for PAHs, 0.2-7.9 pg/µL for hydroxyl and oxy PAHs, 0.1-7.4 pg/µL for nitro PAHs and 0.06-0.3 pg/µL for methyl-PAHs. As an example for the relevance of this method samples of PM10 were collected at six sampling sites in Medellin, Colombia, extracted and the concentration of 64 compounds was determined. The 16 PAHs from the EPA priority list contributed only from 54% to 69% to the sum of all analyzed compounds, PAH with high molecular weight accounted for 8.8%-18.9%. Benzo(a)pyrene equivalents (BaPeq) were calculated for the estimation of the life time cancer (LCR). The LCR according to the samples ranged from 2.75 × 10-5 to 1.4 × 10-4 by a calculation with toxic equivalent factors (TEF) and 5.7 × 10-5 to 3.8 × 10-4 with potency equivalent factor (PEF). By using the new relative potency factors (RPF) recommended by US Environmental Protection Agency (U.S.EPA) the LCR ranged from 1.3 × 10-4 to 7.2 × 10-4. Hence, it was around six times higher than the well-known TEF. The novel method enables the reliable quantification of a more comprehensive set of PAHs bound on PM and thus will facilitate and improve the risk assessment of them.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hidrocarbonetos Policíclicos Aromáticos / Monitoramento Ambiental / Poluentes Atmosféricos Tipo de estudo: Etiology_studies / Risk_factors_studies País/Região como assunto: America do sul / Colombia Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hidrocarbonetos Policíclicos Aromáticos / Monitoramento Ambiental / Poluentes Atmosféricos Tipo de estudo: Etiology_studies / Risk_factors_studies País/Região como assunto: America do sul / Colombia Idioma: En Ano de publicação: 2019 Tipo de documento: Article