Your browser doesn't support javascript.
loading
Impact of b-Value Sampling Scheme on Brain IVIM Parameter Estimation in Healthy Subjects.
Chabert, Stéren; Verdu, Jorge; Huerta, Gamaliel; Montalba, Cristian; Cox, Pablo; Riveros, Rodrigo; Uribe, Sergio; Salas, Rodrigo; Veloz, Alejandro.
Afiliação
  • Chabert S; CINGS Centro de Investigación y Desarrollo de Ingeniería para la Salud, Universidad de Valparaíso.
  • Verdu J; Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso.
  • Huerta G; Millennium Nucleus for Cardiovascular Magnetic Resonance.
  • Montalba C; Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso.
  • Cox P; Universidad Politécnica de Valencia.
  • Riveros R; Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso.
  • Uribe S; Center for Biomedical Imaging, Pontificia Universidad Católica de Chile.
  • Salas R; Servicio de Imagenología, Hospital Carlos van Buren.
  • Veloz A; Servicio de Imagenología, Hospital Carlos van Buren.
Magn Reson Med Sci ; 19(3): 216-226, 2020 Aug 03.
Article em En | MEDLINE | ID: mdl-31611542
PURPOSE: Intravoxel incoherent motion (IVIM) analysis has attracted the interest of the clinical community due to its close relationship with microperfusion. Nevertheless, there is no clear reference protocol for its implementation; one of the questions being which b-value distribution to use. This study aimed to stress the importance of the sampling scheme and to show that an optimized b-value distribution decreases the variance associated with IVIM parameters in the brain with respect to a regular distribution in healthy volunteers. METHODS: Ten volunteers were included in this study; images were acquired on a 1.5T MR scanner. Two distributions of 16 b-values were used: one considered 'regular' due to its close association with that used in other studies, and the other considered 'optimized' according to previous studies. IVIM parameters were adjusted according to the bi-exponential model, using two-step method. Analysis was undertaken in ROI defined using in the Automated Anatomical Labeling atlas, and parameters distributions were compared in a total of 832 ROI. RESULTS: Maps with fewer speckles were obtained with the 'optimized' distribution. Coefficients of variation did not change significantly for the estimation of the diffusion coefficient D but decreased by approximately 39% for the pseudo-diffusion coefficient estimation and by 21% for the perfusion fraction. Distributions of adjusted parameters were found significantly different in 50% of the cases for the perfusion fraction, in 80% of the cases for the pseudo-diffusion coefficient and 17% of the cases for the diffusion coefficient. Observations across brain areas show that the range of average values for IVIM parameters is smaller in the 'optimized' case. CONCLUSION: Using an optimized distribution, data are sampled in a way that the IVIM signal decay is better described and less variance is obtained in the fitted parameters. The increased precision gained could help to detect small variations in IVIM parameters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article