OBJECTIVE: This study evaluated whether the pulmonary artery pulsatility index (PAPi) collected before and after cardiopulmonary bypass (CPB) is predictive and diagnostic of new onset right ventricular (RV) failure in the elective cardiac surgical population. DESIGN: This was a prospective observational study of patients who underwent cardiac surgery between 2017 and 2019. SETTING: Weill Cornell Medicine, a single large academic medical center. PARTICIPANTS: The study comprised 119 patients undergoing elective cardiac surgery. INTERVENTIONS: Cardiopulmonary bypass, transesophageal echocardiography, pulmonary artery catheter, and elective cardiac surgery. MEASUREMENTS AND MAIN RESULTS: Echocardiographic and hemodynamic data were collected at 2 time points: pre-CPB and post-chest closure/post-CPB. Patients with and without post-CPB RV dysfunction fractional area of change (<35%) were compared, and receiver operating characteristic curves were constructed. One hundred and nineteen patients undergoing elective surgery-coronary artery bypass grafting (23%), aortic valve replacement (21%), aortic surgery (19%), and combined surgery (37%)-were evaluated. Post-CPB RV dysfunction was associated with lower pre-CPB PAPi values (2.0 ± 1.0 v 2.5 ± 1.2; pâ¯=â¯0.001 and pâ¯=â¯0.03) and higher pre-CPB central venous pressure (8.3 ± 3.6 and 6.9 ± 2.7; pâ¯=â¯0.003 and pâ¯=â¯0.02, respectively). Pre-CPB PAPi (0.98 [95% confidence interval {CI} 0.96-0.99]), end systolic area (0.99 [95% CI 0.98-0.99]), and end diastolic area (1.01 [95% CI 1.001-1.02]) were independently associated with RV dysfunction in multivariable modeling, with a lower PAPi and end systolic area and higher end diastolic area demonstrating a greater risk of RV dysfunction post-CPB (post-CPB area under the curve for PAPi 0.80 [95% CI 0.71-0.88; sensitivityâ¯=â¯0.68, specificityâ¯=â¯0.93, optimal cutoffâ¯=â¯1.9]). CONCLUSIONS: PAPi measured pre-CPB is a potential predictor and marker of post-CPB RV dysfunction and may have diagnostic utility in cardiac surgery. Additional, large-scale studies are needed to confirm this finding.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Disfunção Ventricular Direita
/
Procedimentos Cirúrgicos Cardíacos
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article