Your browser doesn't support javascript.
loading
Inline extracorporeal photopheresis: evaluation of cell collection efficiency.
Piccirillo, Nicola; Putzulu, Rossana; Massini, Giuseppina; Di Giovanni, Alessia; Chiusolo, Patrizia; Sica, Simona; Zini, Gina.
Afiliação
  • Piccirillo N; Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Putzulu R; Università Cattolica del Sacro Cuore, Roma, Italy.
  • Massini G; Transfusion Medicine Department, Roma, Italy.
  • Di Giovanni A; Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Chiusolo P; Transfusion Medicine Department, Roma, Italy.
  • Sica S; Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Zini G; Transfusion Medicine Department, Roma, Italy.
Transfusion ; 59(12): 3714-3720, 2019 12.
Article em En | MEDLINE | ID: mdl-31682286
ABSTRACT

BACKGROUND:

Extracorporeal photopheresis (ECP) therapy has proved to be an effective and safe treatment for graft-versus-host-disease (GvHD), an important complication after hematopoietic stem cell transplantation. In 2016, we acquired Therakos CellEx, a dedicated inline ECP device to accomplish a significant increase in ECP activity. In literature, we found few data reporting CellEx performance evaluated in terms of collection efficiency to qualify the device. Hence, we decided to collect and analyze our data in order to build a reference in terms of expected results of the procedure. Here we report our data of ECP performed using CellEx in a 12-month period focusing on collection efficiency assessment, as well as procedural and apheretic product characteristics. STUDY DESIGN AND

METHODS:

We collected data of patients undergoing ECP from April 2018 to March 2019 using CellEx in order to evaluate collection efficiency.

RESULTS:

Between April 2018 and March 2019 we treated 28 adult patients affected by GvHD performing 319 ECP using CellEx. CellEx mononuclear cell product was characterized by high mononuclear cell percentage and low percentage of granulocytes, resulting particularly suitable for ECP treatments. Median collection efficiency for total nucleated cells and for mononuclear cells was 31.2% and 62.3%, respectively.

CONCLUSION:

Collection efficiency of CellEx was comparable to that usually obtained by cell separators designed for cell collection and was comparable to that of offline systems. Our results provide a detailed performance evaluation for inline ECP system users.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotoferese / Doença Enxerto-Hospedeiro Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotoferese / Doença Enxerto-Hospedeiro Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article