[A Chinese consensus statement on the clinical application of transesophageal echocardiography for critical care (2019)].
Zhonghua Nei Ke Za Zhi
; 58(12): 869-882, 2019 Dec 01.
Article
em Zh
| MEDLINE
| ID: mdl-31775449
Transesophageal echocardiography(TEE) is valuable in intensive care unit (ICU) because its application meets the requirements of diagnosis and treatment of critically ill patients.However, the current application has not fully adapted to the specialty of critical care. TEE could be more valuablein ICU when used with a new way that under the guidance of the theory of critical care and embedded into the treatment workflow. We have expanded and improved the application of traditional TEE and integrated the concept of critical care, established the concept of transesophageal echocardiography for critical care (TEECC). Chinese Critical Ultrasound Study Group (CCUSG) organized experts in the area to form the consensus based the previous studiesand the long term practice of critical care ultrasound and TEE, aiming at clarifying the nature and characteristics of TEECC, promoting the rational and standardized clinical application and the coming researches.The consensus of Chinese experts on clinical application of TEECC (2019) were 33 in total, of whichthe main items were as follows: (1) TEECC is a significant means, which is expanded and improved from the traditional transesophageal echocardiography according to characteristics of critically ill patients and is applied in ICU based on critically clinical scenarios and requirements by the critical care physician, to promote visualized, refined and precisely management of critically ill patients.(2) TEE possesses distinctive superiority in implementation in ICU. It has characteristics of images with good quality, operations with good stability and low-dependent of operators, monitoring with continuity, and visualization with all-dimensional and detail of heart and blood vessels.(3)As a means of refined monitoring that could resulted in precise diagnosis and treatment, TEECC expands the dimension of intensive monitoring and improves the performance of critical care. (4) Indications of TEECC application include clinical etiological searching and invasive procedures guiding when it acted as a traditional role; and also refined hemodynamic monitoring based on critical care rationale and over-all management under specific critical clinical scenarios. (5) TEE and TTE assessments are complementary; they are not alternative. Integrated assessment of TTE and TEE is required under many critical clinical scenarios.(6) TEE should be a necessary configuration in ICU. (7) All-round and significant information regarding to the mechanism of acute circulatory disorders can be provided by TEECC; it is a non-substitutable means of identifying the causes of shock under some special clinical scenarios. (8) Focal extracardiac hematoma can be accurately and rapidly detected by TEE in patients with open-thoracic cardiac surgery or severe chest trauma when highly suspected pericardial tamponade.(9) The priority of pathophysiologic mechanism of septic shock can be rapidly and accurately identified by TEE; even if its pathophysiological changes are complex, including hypovolemia and/or vasospasm and/or left and right heart dysfunction. (10) Causes of hemodynamic disorders can be rapidly and qualitatively evaluated so that the orientation of treatment can be clarified by TEECC. (11) A full range of quantitative indicators for refined hemodynamic management in critically ill patients can be provided by TEECC. (12) TEECC helps to accurately assess volume status and predict fluid responsiveness.(13) TEECC is specially suitable for accurate quantitative assessment of cardiac function.(14) Mini TEE provides long-term continuous hemodynamic monitoring. (15) Standard views are easy to be acquired by TEECC, which is a premise for accurate and repeatable measurements, and a guarantee for assessment of effect and risk of therapy. (16) Compared with invasive hemodynamic monitoring, TEECC is minimally invasive, with low infection risk and high safety.(17) In patients with acute cor pulmonale (ACP) under condition of right ventricular dysfunction and low cardiac output, TEECC is a key tool for assessment. (18) TEECC should be implemented actively when suspicious of left to right shunt in critically ill patients who occurred hypotension that hard to explain the cause. (19) TEECC should be implemented actively when suspicious of right to left shunt in critically ill patients who occurred hypoxemia that hard to explain the cause. (20) TEECC is preferred in hemodynamics monitoring under prone position of ventilated patients.(21) TEECC is an imperative means to achieve over-all management of extracorporeal membrane oxygenation (ECMO) therapy, especially for all-round hemodynamic monitoring. (22) Three basic views is recommended to be used to simplify TEE assessment during cardiac arrest so that reversible causes could be identified, and resuscitation could be guided. (23) The flow related echodynamic evaluation (TEECC-FREE) workflow is preferred in refined hemodynamics monitoring and therapy. (24) Simple workflow of TEECC could be implemented in special critical clinical scenarios. (25) Application of TEECC is highly secure; however, impairments of procedure should also be alert by operators. (26) Pitfalls in application of TEE should be paid attention to by the critical care physician. (27) Timely and rationally application of TEECC is in favor of diagnosis and treatment of critically ill patients and may improve the prognosis.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ecocardiografia Transesofagiana
/
Cuidados Críticos
/
Consenso
Tipo de estudo:
Guideline
/
Prognostic_studies
Limite:
Humans
País/Região como assunto:
Asia
Idioma:
Zh
Ano de publicação:
2019
Tipo de documento:
Article