Your browser doesn't support javascript.
loading
Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography.
Arendt, Christophe T; Czwikla, Rouben; Lenga, Lukas; Wichmann, Julian L; Albrecht, Moritz H; Booz, Christian; Martin, Simon S; Leithner, Doris; Tischendorf, Patricia; Blandino, Alfredo; Vogl, Thomas J; D'Angelo, Tommaso.
Afiliação
  • Arendt CT; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Czwikla R; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Lenga L; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Wichmann JL; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Albrecht MH; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany. Electronic address: MoritzAlbrecht@gmx.net.
  • Booz C; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Martin SS; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA.
  • Leithner D; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Tischendorf P; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Blandino A; Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy.
  • Vogl TJ; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • D'Angelo T; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany; Section of Radiological Sciences, Department of Biomedical Sciences and Morphological and Functional Imaging, Policlinico G. Martino - University Hospital Messina, Messina, Italy.
Eur J Radiol ; 122: 108666, 2020 Jan.
Article em En | MEDLINE | ID: mdl-31786506
ABSTRACT

PURPOSE:

To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA).

METHOD:

Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ±â€¯13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques.

RESULTS:

Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89).

CONCLUSIONS:

DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Vasos Coronários Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Vasos Coronários Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article