Your browser doesn't support javascript.
loading
Relative Enhanced Diffusivity in Prostate Cancer: Protocol Optimization and Diagnostic Potential.
Billdal, Daniel C; While, Peter T; Selnaes, Kirsten M; Sunoqrot, Mohammed R S; Langørgen, Sverre; Bertilsson, Helena; Bathen, Tone F; Elschot, Mattijs.
Afiliação
  • Billdal DC; Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.
  • While PT; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Selnaes KM; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Sunoqrot MRS; Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.
  • Langørgen S; Department of Circulation and Medical Imaging, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.
  • Bertilsson H; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Bathen TF; Department of Cancer Research and Molecular Medicine, NTNU, Norwegian University of Science and Technology, Trondheim, Norway.
  • Elschot M; Department of Urology, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
J Magn Reson Imaging ; 51(6): 1900-1910, 2020 06.
Article em En | MEDLINE | ID: mdl-31794113
ABSTRACT

BACKGROUND:

Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion-weighted magnetic resonance imaging (MRI) with 3 b values.

PURPOSE:

To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis. STUDY TYPE Prospective. POPULATION Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa. SEQUENCE 3T T2 - and diffusion-weighted MRI with b values b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm2 (values in brackets were only used for patients). ASSESSMENT Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy-confirmed cancer and healthy tissue, and between true and false positive radiological findings. STATISTICAL TESTS Within-subject coefficient of variation (WCV) to assess repeatability and receiver-operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED.

RESULTS:

The repeatability was acceptable (WCV = 0.2-0.3) for all intermediate b values tested, apart from b = 50 s/mm2 (WCV = 0.3-0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150-250 s/mm2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false-positive findings and true-positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77). DATA

CONCLUSION:

RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150-250 s/mm2 minimizes the influence of noise and maximizes repeatability. LEVEL OF EVIDENCE 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2020;511900-1910.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2020 Tipo de documento: Article